IMPORTANT NOTES:

  

Air in the heater may cause the elements to burn out. If the water lines are drained, 
allowing air into the heater, be sure to follow the following start-up procedure: 

 

1.  Turn off electrical supply – open circuit breaker. 
2.  Turn on water supply. 
3.  Expel all air from lines and heater. 
4.  Turn on electrical power supply – close circuit breaker. 

 

 

FIGURE 1 HEATER 

INSTALLATION 

Faucet flow controls must be attached to the faucet to allow the water heating system to operate more effectively  
(See Fig. 2, pg. 3 for installation). 

Item 

Part 

No. 

  Names 

   Qty 

  Description 

 
1. 

SR-_ _L 

Chronomite Instant-Flow SR Heater 

 

Models shown in Table 1 

2. 

  Electrical 

junction 

box 

   

3. 

  Electrical 

conduit     ½” 

conduit, 

length 

as 

required 

 

 

4. 

  Electrical 

wire 

     Electrical 

Wire 

 

5. 

 

 

Dual outlet angle valve   

 

 

½” FPx7/16” comp.x3/8 comp., Brass 

 

 

 

 

 

 

 

 

 

 

Craft P/N R2701R-RGH 

6. 

  Fitting 

(supplied)   2 

 3/8” 

comp 

¼”MP 

7. 

 

 

Copper or flex tubing 

 

 

 

3/8”OD, 5” long (keep short) 

8. 

 

 

Copper or flex tubing 

 

 

 

 

3/8” OD, length as required (keep short) 

9. 

L-412   

Faucet flow control, dual thread   

 

Supplied with Low Flow Heater 

 OR 

 (see 

figure 

#2) 

     SR-15L, 

SR-20L, 

SR-30L  

10. 

LP-412   

Faucet flow control, dual thread   

 

Supplied with Low Flow Heater 

Hot  

Sink 

Mounting 
Flange 

Cold  

#1 

#2 

#3  
Conduit 

#5 

#6 

#7

 

#9 , #10  

#4 

#8 