IMPORTANT NOTES:
Air in the heater may cause the elements to burn out. If the water lines are drained,
allowing air into the heater, be sure to follow the following start-up procedure:
1. Turn off electrical supply – open circuit breaker.
2. Turn on water supply.
3. Expel all air from lines and heater.
4. Turn on electrical power supply – close circuit breaker.
FIGURE 1 HEATER
INSTALLATION
Faucet flow controls must be attached to the faucet to allow the water heating system to operate more effectively
(See Fig. 2, pg. 3 for installation).
Item
Part
No.
Names
Qty
Description
1.
SR-_ _L
Chronomite Instant-Flow SR Heater
1
Models shown in Table 1
2.
Electrical
junction
box
3.
Electrical
conduit ½”
conduit,
length
as
required
4.
Electrical
wire
Electrical
Wire
5.
Dual outlet angle valve
1
½” FPx7/16” comp.x3/8 comp., Brass
Craft P/N R2701R-RGH
6.
Fitting
(supplied) 2
3/8”
comp
x
¼”MP
7.
Copper or flex tubing
1
3/8”OD, 5” long (keep short)
8.
Copper or flex tubing
3/8” OD, length as required (keep short)
9.
L-412
Faucet flow control, dual thread
1
Supplied with Low Flow Heater
OR
(see
figure
#2)
SR-15L,
SR-20L,
SR-30L
10.
LP-412
Faucet flow control, dual thread
1
Supplied with Low Flow Heater
Hot
Sink
Mounting
Flange
Cold
#1
#2
#3
Conduit
#5
#6
#7
#9 , #10
#4
#8