WIRING DIAGRAMS

C1

T1 T2 T3

L1L2L3

3 Phase Delta

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

MOTOR

1O OR 3O

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

To Element Wiring

3O Wiring Only

Cutout

XFMR

X2

H2

H1

X1

Optional
Thermostat
Built-in Or Field Installed

Optional Disconnect Switch

Built-in Or Field Installed

Transformer Color Code Index

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

277

480

H1

BLK

BLK

BLK

BLK

H2

RED

ORG

BRN

BLK/RED

X1

BLK

BLK

BLK

BLK

X2

WHT

WHT

WHT

WHT

X1

YEL

YEL

YEL

YEL

X2

BLU

BLU

BLU

BLU

30-00,32-00  30-40,32-40

Field Wiring
Built-in Or Field Installed
Factory Wiring

Figure A

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

C1

T1 T2 T3

Motor

1Ø Or 3Ø

Standard Motor Connection

Motor

1Ø Or 3Ø

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

1

2

3

8

9

7

10

11

12

To Element Wiring

Optional
Summer Fan Switch
Built-in Or Field
Installed

3Ø Wiring Only

Cutout

XFMR

X2

H2

H1

X1

Optional Thermostat

Built-in Or Field Installed

3Ø Wiring Only

Optional Disconnect Switch

Built-in Or Field Installed

Transformer Color Code Index

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

277

H1

BLK

BLK

BLK

H2

RED

ORG

BRN

X1

BLK

BLK

BLK

X2

WHT

WHT

WHT

X1

YEL

YEL

YEL

X2

BLU

BLU

BLU

30-41,32-41  30-42,32-42  30-44,32-44

C1

T1 T2 T3

L1L2L3

3 Phase Delta

Field Wiring
Built-in Or Field Installed
Factory Wiring

Figure B

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

Transformer Color Code Index

30-45, 32-45  30-43, 32-43

Motor

1O Or 3O

C1

T1 T2 T3

L1 L2 L3

Power
60 HZ

To Element

Wiring

3O 
Wiring
Only

Cutout

X2

H2

H1

X1

Optional

Thermostat

Built-in Or Field Installed

Optional Disconnect 
Switch Built-in Or 
Field Installed

C1

T1 T2 T3

Motor

1O Or 3O

Standard Motor Connection

1

2

3

8

9

7

10 11

12

C1

C3

Optional

Summer

Fan Switch

Built-in Or

Field Installed

C3

Optional
Fan Relay
Built-in
Or Field
Installed

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

277

480

H1

BLK

BLK

BLK

BLK

H2

RED

ORG

BRN

BLK/RED

X1

BLK

BLK

BLK

BLK

X2

WHT

WHT

WHT

WHT

X1

YEL

YEL

YEL

YEL

X2

BLU

BLU

BLU

BLU

C1

T1 T2 T3

3 Phase Delta

Field Wiring
Built-in Or Field Installed
Factory Wiring

L1L2L3

C2

Figure C

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

C1

T1 T2 T3

Motor

1Ø Or 3Ø

Standard Motor Connection

Motor

1Ø Or 3Ø

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

1

2

3

8

9

7

10

11

12

To Element Wiring

Optional
Summer Fan Switch
Built-in Or Field
Installed

3Ø Wiring Only

3Ø Wiring Only

Optional Disconnect Switch

Built-in Or Field Installed

Cutout

Field Installed
Built-in Or Field Installed
Factory Wiring

Optional

Thermostat

Built-in Or Field Installed

31-41,33-41  31-42,33-42  31-44,33-44

C1

C2

Control

Power

By Others

Note:

 480V Heaters Require

Fan Relay For 480V Motor
(See Fig. F)

C1

T1 T2 T3

3 Phase Delta

L1L2L3

Figure E

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

Motor

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

To Element Wiring

3Ø Wiring Only

Cutout

Optional

Thermostat

Built-in Or

Field Installed

Optional Disconnect Switch

Built-in Or Field Installed

34-00,35-00  34-40,35-40

Field Installed
Built-in Or Field Installed
Factory Wiring

C1

T1 T2 T3

3 Phase Delta

L1L2L3

Figure G

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

Motor

1O

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

To Element Wiring

3Ø Wiring
Only

Cutout

Field Installed
Built-in Or Field Installed
Factory Wiring

Optional

Thermostat

Built-in Or

Field Installed

Optional Disconnect Switch

Built-in Or Field Installed

31-00,33-00  31-40,33-40

C1

C2

Control

Power

By Others

C1

T1 T2 T3

3 Phase Delta

L1L2L3

Figure D

C1

T1 T2 T3

L1

L3

1 Phase 2 Or 3 Elem

Motor

1O Or 3O

C1

T1 T2 T3

L1 L2 L3

Power
60 HZ

To Element Wiring

3O Wiring Only

Cutout

Optional

Thermostat

Built-in Or 

Field Installed

Optional Disconnect Switch 

Built-in Or Field Installed

C1

T1 T2 T3

Motor

1O Or 3O

Standard Motor Connection

1

2

3

8

9

7

10 11
12

C1

C3

C3

Optional

Summer

Fan Switch

Built-in Or

Field Installed

C3

Optional

Fan Relay

Built-in Or 

Field 

Installed

C2

Control Power

(By Others)

31-43,33-43  31-45,33-45

T1 T2 T3

C1

T1 T2 T3

3 Phase Delta

L1L2L3

Field Installed
Built-in Or Field Installed
Factory Wiring

Figure F

C1

T1 T2

T3

L1

L3

1 Phase 2 Or 3 Elem

C1

T1 T2 T3

Motor

1Ø Or 3Ø

Standard Motor Connection

Motor

1Ø Or 3Ø

C1

T1 T2 T3

L1

L2

L3

Power
60 HZ

1

2

3

8

9

7

10

11

12

To Element Wiring

Optional
Summer Fan Switch
Built-in Or Field
Installed

3Ø Wiring Only

3Ø Wiring Only

Optional Disconnect Switch
Built-in Or Field Installed

Cutout

Optional Thermostat

Built-in Or Field Installed

34-41,35-41  34-42,35-42  34-44,35-44

Field Installed
Built-in Or Field Installed
Factory Wiring

C1

T1 T2 T3

3 Phase Delta

L1L2L3

Figure H

Содержание LUH

Страница 1: ...0 43 480 10 000 3 12 0 30A 1 LUH D 12 83 208 12 500 3 34 8 50A 1 LUH D 12 23 208 240 9 375 12 500 3 30 1 42 663 20 1 2 17 1 4 11 1 2 50A 1 LUH D 12 43 480 12 500 3 15 1 30A 1 LUH D 15 83 208 15 000 3 41 8 50A 1 LUH D 15 23 208 240 11 250 15 000 3 36 2 51 195 20 1 2 17 1 4 11 1 2 50A 1 LUH D 15 43 480 15 000 3 18 1 30A 1 LUH D 20 23 208 240 15 000 20 000 3 48 0 50A 1 LUH D 20 43 480 20 000 3 24 0 6...

Страница 2: ... C are directed away from room occupants in comfort heating D are directed along the windward side when installed in a build ing exposed to a prevailing wind Locate thermostat on interior partition walls or posts away from cold drafts internal heat sources and away from heater dis charge air streams Small rooms can be heated by one unit heater Where two walls are exposed the heater should be mount...

Страница 3: ...malox Note Dimensions In Bracket Bracket Model Weight Use Number P Q R S T Lbs With WUH 01A 1 3 4 21 1 2 6 3 4 5 1 2 14 15 16 4 1 2 LUH 02 04 05 WUH 02 2 28 7 16 9 1 2 8 3 8 22 1 4 12 1 4 LUH 07 10 12 15 WUH 02 2 28 7 16 9 1 2 8 3 8 22 1 4 12 1 4 LUH 20 25 WUH 03 5 1 2 28 11 16 5 3 1 2 33 1 4 24 1 4 LUH 30 35 40 45 Figure 5 Optional Wall Swivel Mounting Bracket Figure 6 Heater Back View 1 2 Knocko...

Страница 4: ... the same as the supply voltage to the LUH heater 1 Use 14 gauge copper NEC Class 1 600V rated insulated wire Wiring must meet all Local and NEC requirements for 480V service 2 Install the remote fan switch in standard wall box in any con venient location that is protected from traffic or other acci dental damage 3 Connect the 14 gauge copper field wire to the switch lead wires with suitable conne...

Страница 5: ...Motor 1Ø Or 3Ø Standard Motor Connection Motor 1Ø Or 3Ø C1 T1 T2 T3 L1 L2 L3 Power 60 HZ 1 2 3 8 9 7 10 11 12 To Element Wiring Optional Summer Fan Switch Built in Or Field Installed 3Ø Wiring Only 3Ø Wiring Only Optional Disconnect Switch Built in Or Field Installed Cutout Field Installed Built in Or Field Installed Factory Wiring Optional Thermostat Built in Or Field Installed 31 41 33 41 31 42 ...

Страница 6: ...lled Field Installed Built in Or Field Installed Factory Wiring Figure M Field Installed Built in Or Field Installed Factory Wiring Stage 2 Elements Motor 3Ø Stage 1 Elements Contactor C1 C2 T1T2T3 T1T2T3 Fuses KTK 3 Fuses When Req d BL1 BL2 BL3 L2 L1 L3 3 Phase 60 HZ Power AL1 AL2 AL3 31 43 33 43 31 45 33 45 Fan Relay C3 Optional Disconnect Switch Built in Or Field Installed For Use With 480V Cut...

Страница 7: ... 072 303180 007 Contactor 120 50A All 072 303180 008 A J S Transformer All 315 304252 001 32 40 Contactor 120 30A All 072 303180 007 Contactor 120 50A All 072 303180 008 A J Transformer All 315 304252 001 Thermostat SP All 300 049197 003 32 41 Contactor 120 30A All 072 303180 007 Contactor 120 50A All 072 303180 008 Transformer All 315 304252 001 B K Thermostat SP All 300 049197 003 Fan Switch 3PD...

Страница 8: ...o Insure That Motor Will Be Energized With First Stage Heat Operation Figure T Contactors AL3 AL2 AL1 BL1 BL2 BL3 Stage 2 Elements C1 T3 T2 T1 Stage 1 Elements C2 Stage 1 Stage 2 C1 C2 C3 Fan 2 Stage Thermostat By Others Cutouts Optional Disconnect Switch Built in Or Field Installed Fuses When Req d Fuses KTK 3 L1 L2 L3 3 Phase 60 HZ Power Field Installed Built in Or Field Installed Factory Wiring...

Страница 9: ... BLVD OGDEN UT 84404 Phone 1 800 368 2493 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx ...

Отзывы: