WIRING DIAGRAMS

Field Installed
Built-in Or Field Installed
Factory Wiring

Stage 2

Elements

Motor

Stage 1

Elements

Contactor

C1

C2

T1T2T3

T1T2T3

Fuses KTK-3

Fuses

(When Req'd)

BL1

BL2

BL3

L2

L1

L3

3 Phase

60 HZ Power

AL1

AL2 AL3

34-43, 35-43   34-45, 35-45

Fan Relay

C3

Optional Disconnect
Switch Built-in Or
Field Installed

Not For Use With 480V

Cutouts

C1

Optional Thermostat
Built-in Or
Field Installed

Contactor

C2

C3

1

2

3

8

9

7

10 11
12

Summer Fan Switch

Motor

C1

T1T2T3

C2

T1T2T3

Contactor

C2

Standard Motor Connection

Figure R

L1

Contactor

(Typ.)

Fuses

(When Req'd)

AL3

AL2

AL1

BL1

BL2

BL3

Optional Summer
Fan Switch
Built-in Or
Field Installed

Stage 2

Elements

Motor

Cutouts

Note: 

Heater Requires

Fan Relay For 480V Motors
(See Fig. R)

Optional Disconnect
Switch Built-in Or
Field Installed

34-41  34-42  34-44

C1

T3

T2

T1

L2 L3

1

2

3

8

9

7

10

11

12

Stage 1

Elements

Motor

3 Phase,

60 HZ Power

Optional Thermostat
Built-in Or
Field Installed

C1

T1 T2

T3

C2

T1 T2

T3

To Elements

Stage 1

To Elements

Stage 2

Standard Motor Connection

Fuses

KTK-3

C2

T3

T2

T1

Field Wiring
Built-in Or Field Installed
Factory Wiring

Figure Q

Field Installed
Built-in Or Field Installed
Factory Wiring

Transformer

Color Code Index

Stage 2

Elements

MOTOR

Stage 1

Elements

Contactors

C1

C2

T1T2T3

T1T2T3

C3

C2

C1

X1

X2

H2

H1

Contactor

Cutouts

XFMR

Fan

Stage 1

Stage 2

2 Stage Thermostat
(By Others)

Fuses KTK-3

Fuses

(When Req'd)

BL1

BL2

BL3

L2

L1

L3

3 Phase

60 Hz Power

AL1

AL2 AL3

Disconnect
Switch Built-in Or
Field Installed

32-00  30-00

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

480

H1

BLK

BLK

BLK

H2

RED

ORG

BLK/RED

X1

BLK

BLK

BLK

X2

WHT

WHT

WHT

X1

YEL

YEL

YEL

X2

BLU

BLU

BLU

Warning -

 First Stage Of 

Thermostat Must Be 
Connected To Terminals C1 
& C2 To Insure That Motor 
Will Be Energized With First 
Stage Heat Operation

Note: 

For Single Stage

Thermostat, See Fig. J

Figure S

Field Installed
Built-in Or Field Installed

Factory Wiring

Transformer

Color Code Index

Stage 2

Elements

Motor

Stage 1

Elements

C1

C2

T1T2T3

T1 T2T3

C3

C2

C1

X1

X2

H2

H1

Contactor

(Typ.)

XFMR

Stage 1

Fuses

(When Req'd)

BL1

BL2

BL3

3 Phase

60 HZ Power

AL1

AL2 AL3

Disconnect
Switch Built-in Or
Field Installed

30-43  32-43

C4

C3

Heat

Fan

Stage 2

L1 L2 L3

Fuses KTK-3

2 PDT Switch

(By Others)

2 Stage Thermostat
(By Others)

Cutouts

C1
C4
C2
C3

4

2

1

3

Jumper

Fan

Heat

Thermostat

Jumpers

Thermostat

W/sub-base

(By Others)

Alternate Customer Hook Up (1 Stage)

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

480

H1

BLK

BLK

BLK

H2

RED

ORG

BLK/RED

X1

BLK

BLK

BLK

X2

WHT

WHT

WHT

X1

YEL

YEL

YEL

X2

BLU

BLU

BLU

Warning -

 First Stage Of 

Thermostat Must Be 
Connected To Terminals C1 & 
C2 To Insure That Motor Will 
Be Energized With First Stage 
Heat Operation

Figure T

Contactors

AL3

AL2

AL1

BL1

BL2

BL3

Stage 2

Elements

C1

T3

T2

T1

Stage 1

Elements

C2

Stage 1

Stage 2

C1

C2

C3

Fan

2 Stage Thermostat
(By Others)

Cutouts

Optional Disconnect
Switch Built-in Or
Field Installed

Fuses

(When Req'd)

Fuses

KTK-3

L1 L2 L3

3 Phase,

60 HZ Power

Field Installed
Built-in Or Field Installed
Factory Wiring

31-00  33-00

T3

T2

T1

Warning -

 First Stage Of Thermostat

Must Be Connected To Terminals C1 & C2
To Insure That Motor Will Be Energized
With First Stage Heat Operation

Motor

Control Power

(By Others)

Note: 

For Single Stage

Thermostat, See Fig. M

Figure U

Field Installed
Built-in Or
Field Installed
Factory Wiring

Stage 2

Elements

Motor

Stage 1

Elements

C1

T1 T2

T3

C3

C2

C1

Contactor

(Typ.)

Stage 1

Fuses

(When Req'd)

BL1

BL2

BL3

3 Phase

60 HZ Power

AL1

AL2 AL3

Optional Disconnect
Switch Built-in Or
Field Installed

34-43  35-43

C4

C3

Heat

Fan

Stage 2

L1 L2 L3

Fuses KTK-3

2 PDT Switch

(By Others)

2 Stage Thermostat
(By Others)

Cutouts

C1
C4
C2
C3

4

2

1

3

Jumper

Fan

Heat

Thermostat

Jumpers

Thermostat

W/sub-base

(By Others)

Alternate Customer Hook Up (1 Stage)

Warning -

 First Stage Of Thermostat

Must Be Connected To Terminals C1 & C2
To Insure That Motor Will Be Energized
With First Stage Heat Operation

C2

T1T2

T3

Fan

Relay

Figure V

Field Installed
Built-in Or
Field Installed
Factory Wiring

Stage 2

Elements

Motor

Stage 1

Elements

C1

T1T2

T3

C3

C2

C1

Contactor

(Typ.)

Stage 1

Fuses

(When Req'd)

BL1

BL2

BL3

3 Phase

60 HZ Power

AL1

AL2 AL3

Optional Disconnect
Switch Built-in Or
Field Installed

31-45  33-45

C4

C3

Heat

Fan

Stage 2

L1 L2 L3

Fuses KTK-3

2 PDT Switch

(By Others)

2 Stage Thermostat
(By Others)

Cutouts

C1
C4
C2
C3

4

2

1

3

Jumper

Fan

Heat

Thermostat

Jumpers

Thermostat

W/sub-base

(By Others)

Alternate Customer Hook Up (1 Stage)

Warning -

 First Stage Of Thermostat

Must Be Connected To Terminals C1 & C2
To Insure That Motor Will Be Energized
With First Stage Heat Operation

C2

T1T2

T3

Fan
Relay

Control Power

(By Others)

Figure W

Field Installed
Built-in Or Field Installed
Factory Wiring

Transformer Color Code Index

Stage 2

Elements

Motor

Stage 1

Elements

C1

C2

T1T2T3

T1 T2T3

C3

C2

C1

X1

X2

H2

H1

Contactor

(Typ.)

XFMR

Stage 1

Fuses

(When Req'd)

BL1

BL2

BL3

3 Phase

60 HZ Power

AL1

AL2 AL3

Disconnect
Switch Built-in Or
Field Installed

30-45  32-45

C4

C3

Heat

Fan

Stage 2

L1 L2 L3

Fuses KTK-3

2 PDT Switch

(By Others)

2 Stage Thermostat
(By Others)

Cutouts

C1
C4
C2
C3

4

2

1

3

Jumper

Fan

Heat

Thermostat

Jumpers

Thermostat

W/sub-base

(By Others)

Alternate Customer Hook Up (1 Stage)

Warning -

 First Stage Of

Thermostat Must Be Connected
To Terminals C1 & C2
To Insure That Motor Will
Be Energized With First 
Stage Heat Operation

PRI.
VOLT.

 PRI. XFMR

LEAD  CLRS.

120V SEC.

LEAD  CLRS.

24V SEC.

LEAD  CLRS.

208

240

480

H1

BLK

BLK

BLK

H2

RED

ORG

BLK/RED

X1

BLK

BLK

BLK

X2

WHT

WHT

WHT

X1

YEL

YEL

YEL

X2

BLU

BLU

BLU

Figure X

Содержание LUH

Страница 1: ...0 43 480 10 000 3 12 0 30A 1 LUH D 12 83 208 12 500 3 34 8 50A 1 LUH D 12 23 208 240 9 375 12 500 3 30 1 42 663 20 1 2 17 1 4 11 1 2 50A 1 LUH D 12 43 480 12 500 3 15 1 30A 1 LUH D 15 83 208 15 000 3 41 8 50A 1 LUH D 15 23 208 240 11 250 15 000 3 36 2 51 195 20 1 2 17 1 4 11 1 2 50A 1 LUH D 15 43 480 15 000 3 18 1 30A 1 LUH D 20 23 208 240 15 000 20 000 3 48 0 50A 1 LUH D 20 43 480 20 000 3 24 0 6...

Страница 2: ... C are directed away from room occupants in comfort heating D are directed along the windward side when installed in a build ing exposed to a prevailing wind Locate thermostat on interior partition walls or posts away from cold drafts internal heat sources and away from heater dis charge air streams Small rooms can be heated by one unit heater Where two walls are exposed the heater should be mount...

Страница 3: ...malox Note Dimensions In Bracket Bracket Model Weight Use Number P Q R S T Lbs With WUH 01A 1 3 4 21 1 2 6 3 4 5 1 2 14 15 16 4 1 2 LUH 02 04 05 WUH 02 2 28 7 16 9 1 2 8 3 8 22 1 4 12 1 4 LUH 07 10 12 15 WUH 02 2 28 7 16 9 1 2 8 3 8 22 1 4 12 1 4 LUH 20 25 WUH 03 5 1 2 28 11 16 5 3 1 2 33 1 4 24 1 4 LUH 30 35 40 45 Figure 5 Optional Wall Swivel Mounting Bracket Figure 6 Heater Back View 1 2 Knocko...

Страница 4: ... the same as the supply voltage to the LUH heater 1 Use 14 gauge copper NEC Class 1 600V rated insulated wire Wiring must meet all Local and NEC requirements for 480V service 2 Install the remote fan switch in standard wall box in any con venient location that is protected from traffic or other acci dental damage 3 Connect the 14 gauge copper field wire to the switch lead wires with suitable conne...

Страница 5: ...Motor 1Ø Or 3Ø Standard Motor Connection Motor 1Ø Or 3Ø C1 T1 T2 T3 L1 L2 L3 Power 60 HZ 1 2 3 8 9 7 10 11 12 To Element Wiring Optional Summer Fan Switch Built in Or Field Installed 3Ø Wiring Only 3Ø Wiring Only Optional Disconnect Switch Built in Or Field Installed Cutout Field Installed Built in Or Field Installed Factory Wiring Optional Thermostat Built in Or Field Installed 31 41 33 41 31 42 ...

Страница 6: ...lled Field Installed Built in Or Field Installed Factory Wiring Figure M Field Installed Built in Or Field Installed Factory Wiring Stage 2 Elements Motor 3Ø Stage 1 Elements Contactor C1 C2 T1T2T3 T1T2T3 Fuses KTK 3 Fuses When Req d BL1 BL2 BL3 L2 L1 L3 3 Phase 60 HZ Power AL1 AL2 AL3 31 43 33 43 31 45 33 45 Fan Relay C3 Optional Disconnect Switch Built in Or Field Installed For Use With 480V Cut...

Страница 7: ... 072 303180 007 Contactor 120 50A All 072 303180 008 A J S Transformer All 315 304252 001 32 40 Contactor 120 30A All 072 303180 007 Contactor 120 50A All 072 303180 008 A J Transformer All 315 304252 001 Thermostat SP All 300 049197 003 32 41 Contactor 120 30A All 072 303180 007 Contactor 120 50A All 072 303180 008 Transformer All 315 304252 001 B K Thermostat SP All 300 049197 003 Fan Switch 3PD...

Страница 8: ...o Insure That Motor Will Be Energized With First Stage Heat Operation Figure T Contactors AL3 AL2 AL1 BL1 BL2 BL3 Stage 2 Elements C1 T3 T2 T1 Stage 1 Elements C2 Stage 1 Stage 2 C1 C2 C3 Fan 2 Stage Thermostat By Others Cutouts Optional Disconnect Switch Built in Or Field Installed Fuses When Req d Fuses KTK 3 L1 L2 L3 3 Phase 60 HZ Power Field Installed Built in Or Field Installed Factory Wiring...

Страница 9: ... BLVD OGDEN UT 84404 Phone 1 800 368 2493 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx ...

Отзывы: