4.

 

Specification 

4.1

 

Technical Specifications 

Product Code 

CHSONE100V 

Net Dimensions** 
(Without Fixings – W x H x D) 

214mm x 267mm x 232mm / 8.5" x 10.5" x 9" (Full open yoke) 

Net Weight (Without Fixings) 

3.8 kg / 8.5 lb 

Shipping Dimensions –  
Width x Height x Depth 

406mm x 228mm x 292mm / 16" x 9" x 11.5" 

Shipping Weight 

5.5 kg / 12 lb 

Power & Connections 

  

Power Supply 

Built-in 

Power Input Rating 

100-240V AC 50-60Hz 125VA 

Power Factor 

0.5 

Power Consumption 

58W @ 120/230V AC 

Idle Power Consumption 

3.5W @ 120V AC; 5.6W @ 230V AC 

Inrush Current 

15A @ 120V AC; 36A @ 230V AC 

Typical Power & Current 

Measurements done with all LEDs at maximum intensity. Measurements made at nominal 
voltage. Allow for a deviation of +/- 10%. 

Power connector In/Out 

powerCon  

Data Connectors In/Out 

XLR 5-pin 

Control Protocol 

ANSI E1.11 USITT DMX 512-A 

Cooling System 

Convection 

Operating Temperature 

0°C to 40°C 

Construction 

Cast machined aluminium 

Colour 

Black (custom colours available on request) 

Built-In Hardware 

Split yoke, 6.25” Accessory Holder 

IP Rating 

IP20 

Approvals 

CISPR 15/EN55015& EN61547, FCC Part 15 Subpart B:2012 / 
ICES-003:2012, CSA C22.2, UL 1573, IEC 60598 

Control & Photometric 

  

LED Engines 

LEDs Per Engine 

Warm White + Cold White 

Control Modes 

2 channels Color Tempe Intensity, 2 channels Warm White + Cold White 

Dimming Curve 

Theatrical 

Wireless Control  

On / Off, Fade In, Fade Out 

Hot Lumen Output  

2,100 

Optics 

Fully Homogenised 

Beam Angle 

18° (approx) 

Beam Distribution 

Symmetrical direct illumination 

CCT 

3,000K - 6,100K  

CRI 

86 

Lamp Life 

L70 at 50,000 hours 

**

For exact measurements please refer to the line drawings below 

 

 

 

Содержание Studio One 100 V

Страница 1: ...Chroma Q Studio One 100 V User Manual Version 1 0 September 2015 Software Version 1 6 PN 638 0702...

Страница 2: ...by the above e by modification repair or service by anyone other than Chroma Q who has not applied for and been approved by Chroma Q to do such modification repair or service unless the Customer provi...

Страница 3: ...been designed specifically for the lighting industry Regular maintenance should be performed to ensure that the products perform well in the entertainment environment If you experience any difficultie...

Страница 4: ...5 5 2 1 Unpacking the Units 5 2 2 Cabling 5 2 3 Mounting 5 2 4 Optics 5 2 5 Control 6 2 6 DMX Protocol 13 2 7 Thermal Performance 13 3 3 3 3 Troubleshooting Troubleshooting Troubleshooting Troubleshoo...

Страница 5: ...re set also including convection cooling for silent operation and a versatile mounting yoke the Studio One 100 is suitable for numerous TV film studio exhibition entertainment lighting applications co...

Страница 6: ...ant Notice The use of an opto splitter for DMX signal distribution is highly recommended when several fixtures are not plugged into the same power source 2 3 Mounting The Studio One 100 V is built wit...

Страница 7: ...mode level or value Down Arrow Decreases the mode level or value Exit Back to the previous menu Power Up Display On power up the display shows the Brand Model Name and Software Version for 5 seconds...

Страница 8: ...s 4 Slave The unit is set as the Slave unit All settings of the Slave units follow the Master unit Wireless IR Remote The Studio One 100 V can be controlled via wireless IR Remote in standalone operat...

Страница 9: ...wn arrows to navigate the control menu options Press Enter Enter Enter Enter to select a control menu option Press Enter Enter Enter Enter to save the setting display shows Done and returns to the pre...

Страница 10: ...ersonality The Studio One 100 V can be set to operate in DMX controlled and standalone modes Refer to the list below for details To set the Personality 1 From the Main Menu press Up Up Up Up or Down D...

Страница 11: ...ol unit 4 Look 1 Fixture snaps to saved Look 5 Look 2 Fixture snaps to saved Look 6 Look 3 Fixture snaps to saved Look 7 Look 4 Fixture snaps to saved Look 8 Look 5 Fixture snaps to saved Look To set...

Страница 12: ...isplay shows Recorded and the Look turns On To record a Look created from a remote DMX console 1 Set the fixture to the desired Personality 2 Use an external DMX console to adjust the assigned channel...

Страница 13: ...ter the display shows the DMX channel value To display the temperature of the LED Engine in the fixture 1 From the Main Menu press Up Up Up Up or Down Down Down Down to access 4 Technical 2 Press Ente...

Страница 14: ...y Cold White Total 2 DMX channels 2 DMX channels 2 7 Thermal Performance The internal cooling system of the Studio One fixture is by convection and built with automatic protection The fixture s automa...

Страница 15: ...Allow for a deviation of 10 Power connector In Out powerCon Data Connectors In Out XLR 5 pin Control Protocol ANSI E1 11 USITT DMX 512 A Cooling System Convection Operating Temperature 0 C to 40 C Co...

Страница 16: ...ith care the Studio One 100 requires little maintenance However as the unit is likely to be used in a stage environment we recommend periodical internal inspection and cleaning of any resulting dust a...

Отзывы: