Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient
operating temperature of the rack environment may be greater than the
ambient temperature of the room. Therefore, consideration should be
given to installing the equipment in an environment compatible with the
manufacturer’s maximum rated ambient temperature (Tmra) of 35°C
(95°F).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow
required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition
does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the
power supply circuitry and the effect that any possible overloading of
circuits might have on overcurrent protection and power supply wiring.
Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the
rack itself should be grounded. Particular attention should be given to
power supply connections other than the direct connections to the
branch circuit (i.e. the use of power strips, etc.).
Содержание TVC-700
Страница 1: ...TVC 700 U s e r M a n u a l 020 100906 01 ...
Страница 2: ......
Страница 3: ...TVC 700 U s e r M a n u a l 020 100906 01 ...
Страница 14: ...Introduction 8 TVC 700 User Manual 020 100906 01 Rev 1 03 13 ...
Страница 20: ...Install TVC 700 14 TVC 700 User Manual 020 100906 01 Rev 1 03 13 1 Inner rails 2 Chassis handle ...
Страница 26: ...Install TVC 700 20 TVC 700 User Manual 020 100906 01 Rev 1 03 13 ...
Страница 43: ... 000 103463 01 ASSY TECH DOCS TVC 700 ...