Introduction
4
TVC-700 User Manual
020-100906-01 Rev. 1 (03/13)
Reset
The reset button should not be used unless pressing Power fails
to shutdown the system.
Control Panel LEDs
The control panel located on the front of the chassis has several LEDs.
These LEDs provide you with critical information related to different
parts of the system. This section explains what each LED indicates when
illuminated and any corrective action you may need to take.
HDD
Indicates hard drive and/or DVD-ROM drive activity when
flashing.
NIC1
Indicates network activity on the LAN1 port when flashing.
NIC2
Indicates network activity on the LAN2 port when flashing.
Overheat/Fan Fail:
When this LED flashes, it indicates a fan failure. When on
continuously it indicates an overheat condition, which may be
caused by cables obstructing the airflow in the system or the
ambient room temperature being too warm. Check the routing
of the cables and make sure all fans are present and operating normally.
You should also check to make sure that the chassis covers are installed.
Finally, verify that the heatsinks are installed properly. This LED will
remain flashing or on as long as the indicated condition exists.
Содержание TVC-700
Страница 1: ...TVC 700 U s e r M a n u a l 020 100906 01 ...
Страница 2: ......
Страница 3: ...TVC 700 U s e r M a n u a l 020 100906 01 ...
Страница 14: ...Introduction 8 TVC 700 User Manual 020 100906 01 Rev 1 03 13 ...
Страница 20: ...Install TVC 700 14 TVC 700 User Manual 020 100906 01 Rev 1 03 13 1 Inner rails 2 Chassis handle ...
Страница 26: ...Install TVC 700 20 TVC 700 User Manual 020 100906 01 Rev 1 03 13 ...
Страница 43: ... 000 103463 01 ASSY TECH DOCS TVC 700 ...