Страница 4: ...h high quality materials and components that can be recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from regular waste Please dispose of the product appropriately and according to local regulations In the European Union there are separate collection systems for used electrical and electronic products Please help u...

Страница 5: ... Components 2 3 2 4 2 Main Chassis Front Panel LEDS and Buttons 2 4 2 4 3 Main Chassis Rear Panel Components 2 5 2 4 4 Rear Panel Chassis LEDS 2 6 2 5 Redundant Array of Independent Disks RAID 2 7 2 5 1 Configurations 2 7 Recognizing Hard Drive Failures 2 7 Effects of Hard Drive Failures 2 7 2 6 Disk Replacement Automatic Rebuild 2 7 3 Connecting the Controller 3 1 Grounding the Expansion Chassis ...

Страница 6: ... 5 Recognizing Expansion Chassis Power Supply Failures 3 13 3 10 Network Adapter Teaming 3 13 4 Specifications 4 1 Hardware 4 1 4 1 1 Main Chassis 4 1 4 1 2 Main Memory 4 1 4 1 3 I O Interfaces 4 1 4 1 4 Integrated SATA Storage Controller 4 2 4 1 5 Embedded PCI Express Gigabit NIC Server Adapter 4 2 4 1 6 Expansion Chassis 16 Slot 4 2 4 1 7 Expansion Chassis 13 Slot 4 2 4 2 Power Requirements 4 3 ...

Страница 7: ...11 User Manual iii 020 100769 01 Rev 4 05 2012 4 6 3 Certification Marks 4 9 4 7 Reliability and Serviceability 4 9 4 8 Quality 4 9 4 9 Environment 4 10 4 9 1 Operating 4 10 4 9 2 Non Operating 4 10 Storage 4 10 Shipping 4 10 ...

Страница 8: ......

Страница 9: ...te injury NOTICE Addresses practices not related to personal injury 1 2 Related Documents MASTERSuite User Manual P N 020 100563 xx 1 3 Safety Information Review this section before attempting to service the TVC 1211 controller 1 3 1 Prevent Electrostatic Discharge Electrostatic discharge ESD can damage electronic components ESD damage can shorten a component s life expectancy or render it useless...

Страница 10: ... unrestricted airflow around the installed equipment at all times For rack installation it is recommended to leave a minimum of 1U 1 75 44 45 mm above the expansion chassis Mechanical Loading Avoid uneven mechanical loading to minimize possible hazardous conditions when mounting the equipment in a rack Circuit Overloading Ensure the equipment is properly connected to the supply circuit and follow ...

Страница 11: ... or hot component Contact with the hot surface may cause personal injury WARNING To reduce the risk of injury from a hot component allow the surface to cool before touching 24 41 kg 55 90 lbs This symbol indicates the component exceeds the recommended weight that one person may handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health ...

Страница 12: ......

Страница 13: ...ch with 16 slot 8 PCI X and 8 PCI switch fabric backplane or 13 slot PCI backplane Cosmetic customizing for consistent look and feel of main and expansion chassis Redundant hot plug power supplies Redundant chassis cooling fans Intel Xeon Quad Core Processor 4GB of DDR3 SDRAM 500GB of redundant SATA hardware storage Integrated RAID support 2 Gigabit Ethernet ports 4 USB 2 0 ports 1 serial port 1 k...

Страница 14: ...020 100563 xx MASTERSuite Installation Guide P N 020 100566 xx TVC 1211 User Manual P N 020 100769 xx Keyboard Mouse 1 AC line cord per power supply 2 per controller HP SmartStart CD required for Windows reinstall TVC Expansion Chassis Expansion Chassis Accessories Box Sliding rail rack mounting kit 1 AC line cord per power supply 4 per chassis Dual VGA splitter cables 2 per D4A module Dual DVI D ...

Страница 15: ...m In North America call toll free 1 800 221 8025 Updated contact information can be found at www christiedigital com Fill out the information in the table below and keep with your records for future reference NOTE The serial number can be found on the license label 2 4 Component Identification 2 4 1 Main Chassis Front Panel Components 1 Hard drive bays x6 2 USB connectors 3 DVD RW drive Purchase R...

Страница 16: ...STANDBY or power cap disabled 3 System Power LED Green Power On Flashing Green Waiting for power due to group power capping Amber System in STANDBY but power still ON OFF Power cord not attached or power supply failure 4 UID LED Blue Activated Flashing System managed remotely OFF Deactivated 5 NIC 1 Activity LED Green Network link Flashing Network link and activity OFF No link to network If power ...

Страница 17: ...100769 01 Rev 4 05 2012 2 4 3 Main Chassis Rear Panel Components 1 Redundant Hot Plug Power Supply Module 6 Onboard Graphics Port 2 AC Inlet 7 USB Ports 3 PS 2 Mouse Port 8 RJ 45 Onboard Ethernet Ports 4 PS 2 Keyboard Port 9 PCIe Slots 5 Serial Port ...

Страница 18: ...DS Item Description Status 1 Power Supply LEDs Green Power supply is ON and functioning OFF No power 2 Not used 3 Not used 4 Not used 5 10 100 1000 NIC Link LED Green Linked to network OFF Not linked to network 6 10 100 1000 NIC Activity LED Green or Flashing Network activity OFF No network activity ...

Страница 19: ... to lose data 2 6 Disk Replacement Automatic Rebuild When replacing a failed drive in a RAID configuration the system automatically starts data recovery When the failed drive is replaced while the system is powered ON all disk activity pauses while the drive spins up Once the drive has reached operating speed data recovery begins If you replace a drive when the system is powered OFF a POST message...

Страница 20: ......

Страница 21: ...eliable earth ground Install the ground wire in accordance with local electrical safety standards Refer to Grounding the Expansion Chassis on page 1 2 3 2 Connecting the Expansion Chassis to the Controller Connect the expansion host card controller to the expansion slave card expansion chassis with the specialized cable provided The connectors and cable are keyed TVC 1211 Controller Host Card TVC ...

Страница 22: ... 020 100769 01 Rev 4 05 2012 Section 3 Connecting the Controller 3 2 1 Connecting Multiple 13 slot Chassis Up to 2 chassis can be connected PCIe Host Card Slave Card Slave Card Host Card Expansion Chassis 1 Expansion Chassis 2 ...

Страница 23: ... the Controller TVC 1211 User Manual 3 3 020 100769 01 Rev 4 05 2012 3 2 2 Connecting Multiple 16 slot Expansion Chassis PCIe Host Card Host Card ES16SF Slave Card ES16SF Slave Card Expansion Chassis 1 Expansion Chassis 2 ...

Страница 24: ...on 3 3 1 13 slot Expansion Chassis Channel Numbering and Section 3 3 2 16 slot Expansion Chassis Channel Numbering illustrate how the cards installed in the TVC 1211 and the expansion chassis translate to channels in MASTERSuite 3 3 1 13 slot Expansion Chassis Channel Numbering PCIe Host Card Slave Card V16A 97 128 V16A 65 96 V16A 33 64 V16A 1 32 D4 A 5 8 D4A 9 12 D4A 13 16 D2R2 1 2 D2R2 3 4 D2R2 ...

Страница 25: ... The controller comes pre configured according to your specifications You should be able to connect your sources and display content on the display wall when the unit is unpacked This section provides a high level overview of the capabilities of the modules available for this controller It also touches on some system configuration information All input and display modules are clearly labeled Compo...

Страница 26: ...ny of the available BNC inputs To hook up S video connect Y Luma to the A input and C Chroma to the corresponding B input Refer to the illustration below A single V16A module can connect up to 32 composite or 16 S video signal sources simultaneously Up to 16 simultaneous video windows per V16A can be opened on the display wall D2R2 Module Up to a maximum of 16 D2R2 modules can be installed into a ...

Страница 27: ...o number your display devices By software default display numbering begins from the top left of the display wall and continues across each row and down 3 5 2 DVI D Cables When connecting DVI D cables the controller and display devices must be powered down DVI D connection requires Extended Display Identification Data EDID which is detected at startup 1 Connect the single end of each of the 2 dual ...

Страница 28: ...intained for some time after the MediaManager window is closed Changing the resolution while this overlay is active can cause unpredictable behavior Restart the system before changing the resolution 4 Check the Force DVI checkbox 5 Power down the controller 6 Reconnect the DVI cable for Display 1 7 Power up the display devices and the controller NOTE If you still do not see output on the DVI displ...

Страница 29: ...ipment must be grounded to a reliable earth ground The ground must be installed in accordance with local electrical safety standards The expansion chassis has 4 power supplies Ensure all power supplies are connected during normal operation 3 8 Powering ON OFF NOTICE If this is the very first time the server is powered ON please refer to the start up instruction sheet supplied with the controller f...

Страница 30: ...e front panel Power ON Standby button does not completely shutoff system power Portions of the power supply and some internal circuitry remain active until AC power is removed If you are powering down for maintenance you must also remove the power cord from each power supply Failure to remove the power cords may increase the risk of personal injury electric shock or damage to the equipment NOTICE ...

Страница 31: ...activity LED embedded NIC only Green Linked to network Flashing Green Linked with activity on network OFF No network connection 3 NIC1 link activity LED embedded NIC only Green Linked to network Flashing Green Linked with activity on network OFF No network connection 4 Power cap Green Power cap configured Flashing Amber Power cap exceeded OFF Server in STANDBY or power cap disabled 5 Internal syst...

Страница 32: ...ation and cause data loss The drive is part of an array that is undergoing capacity expansion or stripe migration but a predictive failure alert has been received for this drive To minimize risk of data loss do not replace the drive until the expansion or migration is complete Flashing Regularly 1 Hz OFF DO NOT remove the drive Removing the drive may terminate the current operation and cause data ...

Страница 33: ...which power supply has been disconnected or failed LED OFF To disable the alarm press the Alarm Reset button located to the left of the Power switch Add connect or replace the failed power supply module s as soon as possible The expansion chassis continues to operate with a minimum of 3 power supplies in non redundant mode 3 10 Network Adapter Teaming The TVC 1211 provides basic teaming with setup...

Страница 34: ......

Страница 35: ...ector full length full height Slot 4 PCI Express Gen 2 x 8 slot with x16 connector full length full height Slot 5 PCI Express Gen 2 x 4 slot with x8 connector full length full height Slot 6 PCI Express Gen 2 x 4 slot with x8 connector full length full height Cooling PCI Memory CPU 3x cooling fans Monitoring CPU NICs Temperature Fans Power supplies Drive controllers Disk Drives Chipset Intel 5520 P...

Страница 36: ...3u 100Base TX IEE 802 3ab 1000Base T Data Transfer Method PCI Express four lanes x4 Network Transfer Rate 10Base T Half Duplex 10 Mb s 10Base T Full Duplex 20 Mb s 100Base TX Half Duplex 100 Mb s 100Base TX Full Duplex 200 Mb s 1000Base TX Half Full Duplex 2000 Mb s 4 1 6 Expansion Chassis 16 Slot Expansion Slots 64 bit 66MHz PCI X Slots 8 32 bit 66MHz PCI Slots 8 Cooling 3x chassis cooling fans 1...

Страница 37: ...Hz Rated input current 8 0 4 0A Rated input power 500W Redundant 3 active 1 redundant Hot swappable Yes Table 4 1 Nominal Input Voltage Values Nominal Input Voltage Vrms 100 120 200 208 220 230 240 Max Rated Output Wattage Rating 460 460 460 460 460 460 460 Nom Input Current A rms 5 5 4 5 2 69 2 5 2 4 2 3 2 2 Max Rated Input Wattage Rating Watts 526 520 505 505 503 503 503 Max Rated VA Volt Amp 54...

Страница 38: ...1 3 cm 0 5 Width in housing 7 5 cm 3 0 without housing 7 0 cm 2 8 Interface Serial ATA Transfer Rate Maximum External 3 GB s Internal 300MB s Seek Time typical reads includes setting Average 4 16ms Random read 8 0ms Random write 8 5ms Rotational speed 7200 rpm Standard Configuration 2x500 GB Drives with RAID 1 4 3 1 Peripheral Devices Keyboard Type Standard Interface USB Mouse Type 2 button optica...

Страница 39: ...Overlay Windows 16 per output channel 64 windows per card Max Cards per Expansion Chassis 6 24 display channels Max Cards per System 12 48 display channels Overlay Frame Buffer Resolution 1280x1024x4 Digital Advanced Video Input Bus Speed 5Gb s Max Digital Video Channels per Bus 128 Video Window Update Rate Real time 25 30 fps PAL NTSC Standard Output Connector Type HD15 VGA Optional Output Connec...

Страница 40: ...x 768 60 70 75 85 100 130 Yes 1064 x 600 60 Yes 1152 x 864 60 70 75 85 100 Yes 1248 x 702 60 Yes 1280 x 720 60 70 Yes 1280 x 768 56 60 70 Yes 1280 x 800 60 Yes 1280 x 960 60 85 Yes 1280 x 1024 57 60 75 85 Yes 1280 x 1024 100 No 1360 x 765 60 Yes 1360 x 768 1400 x 1050 60 75 Yes 1400 x 1050 85 100 No 1600 x 1200 30 36 37 42 56 59 60 Yes 1600 x 1200 75 85 100 No 1704 x 960 60 Yes 1792 x 1344 60 75 N...

Страница 41: ...0 SECAM B SECAM D SECAM G SECAM K SECAM L SECAM L SECAM LD Input Levels Composite Video 1 0 Vp p 3dB including sync tip S Video Luma Y 1 0 Vp p 3dB including sync tip S Video Chroma C 630 mVp p nominal burst Connector Type BNC DC Offset 2V Nominal Impedance 75 ohms VS16 Bandwidth 60 MHz 3dB Crosstalk 80dB 20kHz V16A 4 5 2 Standard Input VGA Connectors D2R2 NOTES 1 Sync signals cannot be swapped be...

Страница 42: ...hannels Max cards per system 16 32 capture channels Frame rate Depends on resolution see below Resolution digital 640x480 VGA 800x600 1024x768 1280x1024 1600x1200 1920x1080 1920x1200 WUXGA Resolution analog 640x480 VGA 800x600 1024x768 1280x1024 1600x1200 1920x1080 2048x1536 QXGA Bandwidth 480MB s Video bus PCI X Wall placement Anywhere on the display wall HDCP Not supported Analog input range Min...

Страница 43: ...R 15 minutes max 4 8 Quality ISO 9001 2000 Manufactured in Christie s Canadian facility certified for ISO 9001 2000 and ISO 14001 2004 ISO 14001 2004 4 9 Environment 4 9 1 Operating Temperature 10 C to 35 C 50 F to 95 F Humidity 15 to 80 non condensing Altitude 0 to 2000m 6 562 ft 4 9 2 Non Operating Storage Temperature 20 C to 40 C 4 F to 104 F Humidity 5 to 90 non condensing Thermal Shock 20 C t...

Страница 44: ......

Страница 45: ... 000 103039 01 ASSY TECH DOCS TVC 1211 ...

Страница 46: ...s ph 714 236 8610 Canada Kitchener ph 519 744 8005 United Kingdom ph 44 118 977 8000 France ph 33 0 1 41 21 00 36 Germany ph 49 2161 664540 Eastern Europe ph 36 0 1 47 48 100 Middle East ph 971 0 4 299 7575 Spain ph 34 91 633 9990 Singapore ph 65 6877 8737 Beijing ph 86 10 6561 0240 Shanghai ph 86 21 6278 7708 Corporate offices Worldwide offices ...