Calibrating the lens motor
Ensure the lens motor is calibrated before using the projector.
If the lens motors are not calibrated properly, implications may include:
•
Incorrect reporting of the lens motor position.
•
Inability to use the full range of the lens motors.
•
Lens motors traveling outside of the pre-defined keep-out area.
•
Damage to the projector.
Calibrate the lens motors when any of the following conditions are met:
•
After a lens change.
•
After the projector is moved and/or jostled.
•
After any manual adjustment is made to the zoom or focus.
To calibrate the lens:
1. Select MENU > Configuration > Lens Settings > Lens Calibration.
2. Select Enter.
Removing the projection lens
Use the correct method of removing the lens.
1. Push in and hold the lens release button.
2. Turn the lens counterclockwise until the lens guides are aligned.
3. Slide the lens straight out of the projector.
If the lens does not slide out easily, reset the lens offset before removing the lens.