Serial Commands
Christie MicroTiles Serial Commands Technical Reference
12
020-101547-01 Rev. 1 (03-2015)
Examples
LST–List Displays
Returns a list of all the displays in the current array.
Commands
Examples
LNQ+REST
Resets the error count on channel 1 (HSSL Port 1) and channel 2 (HSSL Port 2).
Notes:
• The user should reset the error count first with (
LNQ+REST
) before requesting
link quality.
• The user should perform multiple requests (
LNQ?
) to see if the error count
increase in subsequent request.
• Under normal operating condition, the error count shall be stable and not
increasing. Rapidly increasing error count usually indicates cabling issue.
-
Get the link quality of the MicroTiles.
(MMP+LIST?)
The following results are displayed:
Index Serial Ch1 Error Count Ch2 Error Count
0 0x0023ed84 0 0
1 0x0023effb 30 0
2 0x0024ccc3 0 8
3 0x0024cfd9 0 32
This indicates tile 1 has 30 errors on Ch1 (HSSL Port 1) and tile 3 has 32 errors on Ch2 (HSSL Port 2).
A small amount of errors are normal, as long as they are not increasing on subsequent requests.
Command
Description
Values
LST?
Returns a list of all displays in the current array.
-
LST+TILS?
Returns a list of all MicroTiles.
-
LST+ECUS?
Returns a list of all ECUs.
-
LST+ARRY?
Returns a list of all components in the array.
-
LST+NGBR?
Returns a list of all neighbors.
-
Command
Description
Values