Serial Command Reference
Mirage WQ-L User Manual
81
020-101372-01 Rev. 1 (04-2014)
• Access Level: Operator
Examples
Edge Blending (EBL)
Error Message Enable (EME)
Set 3D dark interval to 0 on main video
DRK 0
Set 3D dark interval to 3.00 milliseconds
DRK 300
EBL
CONTROL GROUP:
Configuration/Preference
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
This serial command controls edge blending settings.
Subcode
SLCT
Description of Use
Select edge blending mode:
0 = disabled
2 to 17 = select TWIST edge blending maps
Examples:
(EBL+SLCT0) - Edge blending disabled.
(EBL+SLCT2) - Use TWIST edge blending map #1.
EME
CONTROL GROUP:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
This control enables the displaying of error messages, and determines to which interface the messages are sent.
Error messages can be turned Of or can be sent out the serial port. This setting does not affect messages for
invalid user entries, for which error messages are always displayed.
Valid values are:
• 0 = Off
• 2 = Serial ports
Subcode
<No Subcode >
Description of Use
EXAMPLE:
(EME ?) Get current Error Message Enable state.
(ESM ?) Set Error Message Enable to send errors out serial ports.
Содержание Mirage WQ-L
Страница 1: ...Mirage WQ L U s e r M a n u a l 020 101372 01 ...
Страница 10: ...Mirage WQ L User Manual 10 020 101372 01 Rev 1 04 2014 Input Switching 111 ArrayLOC 111 Specifications 112 ...
Страница 93: ...Serial Command Reference Mirage WQ L User Manual 93 020 101372 01 Rev 1 04 2014 Example n a ...
Страница 114: ......
Страница 116: ...For the most current technical documentation please visit www christiedigital com ...