Use the LVPS status table to help determine a resolution.
LED status
Output status
Action
Solid green
DC Output OK
Indicates power to the power supplies. Proceed to
step 3.
Solid orange
DC Output OK, in remote
control mode
Check the communication (CN2) harness into the
power supply is fully seated and connected.
Slow blinking green Output Not Enabled
There is power but the supply is not enabled.
Check the communication (CN2) harness into the
power supply is fully seated and connected.
Fast blinking red
Over Voltage
Too much power is coming into the power supply.
Ensure a certified electrician checks the line voltage
and supply from the wall.
Solid red
Over Loaded
A potential short in the output of the power supply
occurred.
Inspect the DC (secondary) harnesses are fully
seated and connected.
Inspect the boards to ensure they are
functioning.
Slow blinking red
Over Temperature
The power supply has over heated.
Potential air blockage. Inspect the air intake to
the power supply and clear any blockages.
Check if the projector is operating in the
specified projector temperature range.