020-101377-03 Rev. 1 (07-2015)
Adjust the yoke assembly
After installing the lamp, to ensure optimal operation of the lamp,
check that the anode yoke is in the correct position for the lamp
type:
Inspect and clean the lamp
• Check the contact surfaces of the anode (positive) and the cathode (negative) connections for
cleanliness.
• Clean electrical contact surfaces regularly to prevent contact resistance from scorching
connectors. Use an approved contact cleaner such as Sticklers Fiber Optic Cleaner.
• Verify that all electrical and lamp connections are secure.
• Use lint-free lab gloves.
Remove dust from the lamp
1. Brush most of the dust off with a camelhair brush or use a dust-free blower.
2. If some dust remains, leave it. Some dust is inevitable. Avoid unnecessary cleaning.
Remove fingerprints, smudges, or oil from the lamp
1. Brush most of the dust off with a camelhair brush or use a dust-free blower.
2. Fold a microfiber cloth and wipe the remaining dust particles off the lamp with the smooth
portion of the cloth that has no folds or creases. Do not apply finger pressure. Instead, use the
tension in the folded cloth to remove the dust.
Lamp
Type
Anode Yoke Position
2.0 kW
3.0 kW
CDXL-20
CDXL-20SP
CDXL-30
CDXL-30SP
Move the lamp cradle to the rear position,
which is approximately 1” closer to the
reflector.
4.5 kW
6.0 kW
CDXL-45
CDXL-60
Move the lamp cradle as far forward as possible
(position closest to the igniter).
Danger!
Failure to comply with the following results in death or serious injury.
Always disconnect the projector from AC power and wear authorized protective safety gear.
Reflector
Anode
Yoke
Assembly
5mm hex key