Mirage 4K35 User Manual
21
020-101377-03 Rev. 1 (07-2015)
Installation and Setup
Learn how to install, connect, and optimize the projector display.
Site requirements
To safely install and operate the projector, the installation location must have restricted access for
authorized personnel only and meet these minimum requirements.
Physical operating environment
Provides specifications for the operating environment.
• Maximum ambient temperature (operating) 35°C (95°F)
• Minimum ambient temperature (operating) 10°C (50°F)
External exhaust ducting
The installation site must provide a minimum of 450 CFM (ft 3/min) external exhaust airflow to
ensure adequate cooling of the Xenon arc lamp at less than or equal to 25°C (77°F) ambient and
less than 3,000 ft (914.4 m) elevation. Above 25°C or 3,000 ft, 600 CFM is required.
For more details, see
Connect external exhaust ducting
on page 33.
Power connection
The requirements listed below are applicable for permanently wired installation or power cord
connection:
• Single phase 15A IEC320C14 (lamp power supply to projector head)
• Terminal block, electrician hard-wired to the projector head.
Three-phase, 38A 200- Earth (North America and Japan)
or
Three-phase, 26A 380- N Earth (regions outside North America and Japan)
• This product can be connected to an IT power distribution system.