
120
LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide
020-000786-0
2
LIT MAN USR D2
Indicator Status
Description
The air filter is clogged or
dirty.
(
110
)
Check and clean the air filter.
Make sure the power cable is not plugged in, then
allow the projector to cool sufficiently.
See the section "There is a possibility that the
interior portion has become heated" (
119
).
PIN LOCK function is active.
See SECURITY menu > PIN LOCK
(
103
)
If the same indication is displayed after the remedy,
contact your dealer or service company.
The mechanical shutter is closed.
Press the SHUTTER button on the remote control or
on the control panel to open the mechanical shutter.
There is a possibility that the interior portion
has become overcooled.
• Use the unit within the temperature range.
NORMAL MODE: 0 to 40°C
ECO MODE: 0 to 45°C
(continued on next page)
Regarding the indicator lamps
Regarding the indicator lamps (continued)
Orange or Red
Yellow
Yellow
Red
Blinking
alternately
Green
Содержание LW651i
Страница 131: ......