Follow these steps to replace the lamp.
5
Lamp Replacement
For continued safety, replace with a lamp
assembly of the same type.
Do not drop the lamp assembly or touch a glass
bulb! The glass can shatter and may cause injury.
Allow the projector to cool, for at least 45 minutes
before you open Lamp Cover. The inside of the
projector can become very hot.
CAUTION
CAUTION
When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the
screen and LAMP 1/2
REPLACE indicator lights orange. Replace the lamp with a new one promptly. The timing
when the LAMP 1/2 REPLACE indicator should light is depending on the lamp mode.
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer.
When ordering a Projection Lamp, give the following
information to the dealer.
●
Model No. of your projector
L2K1000
●
Replacement Lamp Type No.
002-120598-01
(Service Parts No. 610 351 5939)
Indicators
LAMP 1 / 2 REPLACE indicators
Lamp replacement icon
Check the number of lamp to be replaced on the Lamp Status
Display.
Loosen a screw on the Lamp Cover. Slide and open the Lamp
Cover. (See the right figure.)
Loosen two screws and pull out the Lamp to be replaced by
grasping handle.
Turn off the projector, press the Main On/Off Switch to Off and
unplug the AC power cord from the AC outlet. Let the projector
cool for at least 45 minutes.
Replace the Lamp with a new one and tighten two screws.
Make sure the Lamp is set properly.
Put the Lamp Cover back and tighten a screw.
CAUTION : DO NOT OPERATE THE
PROjECTOR WHILE ANy OF
LAMPS IS REMOVED. IT MAy
RESULT IN MALFUNCTIONS,
FIRE HAZARD, OR OTHER
ACCIDENTS.
NOTES ON LAMP REPLACEMENT
To maintain quality of picture (better
balance of color and brightness in
entire screen), we recommend replacing
both 2 lamps at a time.
SCREW
LAMP
COVER
SCREWS
Make sure which number of lamp needs to be
replaced on Lamp Status Display.
Figure shows case of replacing LAMP 1.
LAMP 2
LAMP 1