Installing a display panel
22
default, use the following values on the computer:
•
IP address: 10.10.10.202
•
Subnet mask: 255.255.255.0
3.
Turn off any browser pop-up blockers.
4.
In the browser address bar, type the IP address of the Remote Power Rack Shelf device.
The default IP address is 10.10.10.201.
If you have changed the IP address of the Remote Power Rack Shelf, the IP address and subnet mask
of the computer must also be changed.
The IP address for the web interface is one digit higher than the IP address of the device. For
example, when the IP address of the device is 10.10.10.201, the address of the web interface is
10.10.10.202.
5.
If prompted, run the MSXML add-on.
6.
Log in to the Remote Power Rack Shelf with your username and password.
The default username is
Admin
, and the default password is
1234
.
Changing the voltage of the rectifiers
Change the output voltage to the preferred voltage.
1.
Log in to the Remote Power Supply Rack Shelf web interface
(on page 21).
2.
Select
Rectifiers
>
Configure Rectifiers
.
3.
Change the Float Voltage field to the preferred voltage.
The recommended voltage range is 48 VDC - 58 VDC.
4.
Ensure the Safe Voltage and Over Voltage Protection (OVP) fields are set properly for the new voltage.
The below is the nominal (Default) settings:
•
Float voltage: 48 VDC
•
Equalize voltage: 49 VDC
•
Safe voltage: 48.5 VDC
•
OVP: 59 VDC
•
HVA: 55.5 VDC
5.
Click
Submit Changes
.
Changing the IP address of the Remote Power Rack Shelf
In an environment where there are multiple Remote Power Rack Shelf devices, you must have a unique IP
address for each device.
1.
Select
Communications
>
Configure Communication Parameters.
2.
Set the new IP address for the Remote Power Rack Shelf.
3.
Click
Submit Changes
.
After the IP address has been changed from the web interface, close the browser window and then
open it using the new IP address.
If you have changed the IP address of the Remote Power Rack Shelf, the IP address and subnet mask
of the computer must also be changed.