Installation and Setup
D4K3560 Setup Guide
19
020-101161-05 Rev. 1 (06-2015)
c.
Reinstall and secure the LPS side panel with six screws.
6. Connect one end of the line cord into the LPS power connector labeled
Projector ONLY
.
If using the longer DC cable kits, the projector head must be powered separately using Christie
recommended line cord provided for your region.
7. Connect the other end of the projector line cord into the plug on the bottom lamp-side of the
projector front bezel.
8. If using a Christie extractor, connect the line cord to the LPS connector labeled
Extractor
ONLY
.
9. Verify the LPS to projector connections by making sure that all cables connected to the LPS are
connected to the same projector.
10. Set the three LPS breakers to their on positions.
11. Set the projector breaker, located on the baseplate below the projector AC receptacle, to the on
position.
Notice.
Failure to comply with the following may result in property damage.
Internal input line voltage switch setting must match AC available on site.
Warning!
Failure to comply with the following could result in death or serious injury.
Do
not
access projector power directly from the building electrical source. When using the
power connectors to power the projector and/or an extraction unit, the power connector
terminal block must be terminated correctly to allow 200 - 240 VAC output. These
connectors are controlled with the power connector breaker. For details, see the
Interconnect Drawing provided with the projector.
Danger!
Failure to comply with the following results in death or serious injury.
In a multi-projector installation there is a risk of a Fire Hazard if the high current DC cables
and interlock/control cables are incorrectly cross-connected between the projector heads
and lamp power supplies (LPSs). Make sure the high current DC Llds and interlock/control
cables are correctly connected between the LPS and its corresponding projector. Failure to
comply may result in a Fire Hazard.