Installation and Setup
D4K3560 Setup Guide
18
020-101161-05 Rev. 1 (06-2015)
c. Connect the projector end of the cable to the port labeled
RS232
, located on the
underside of the projector chassis.
d. Connect the projector end of the Interlock cable to the port labeled
Interlock
, located
on the underside of the projector chassis.
4. Connect the LPS lamp leads:
a. Route the positive (+) cable through the upper strain relief in the LPS cover.
b. Route the negative (-) cable through the lower strain relief in the LPS cover.
c. Connect the positive (+) and negative (-) lamp leads to the terminals on the LPS.
d. Tighten the strain reliefs.
e. Pull the spring plunger to open the igniter door. The door can also be lifted off the hinges
to remove it completely.
f. Route the positive (+) and negative (-) leads from the LPS through the two strain reliefs
in the projector baseplate.
g. Connect the negative (-) black lamp lead to the negative (-) igniter terminal, left
terminal. Connect the positive (+) red lamp lead to the positive (+) igniter terminal, right
terminal.
h. Tighten the strain reliefs.
i. Replace the igniter door.
j. Replace the rear lens-side cover.
5. Ensuring AC power is off at the supply, connect the AC directly to the LPS AC input terminal
block according to your region.
• For North America, Japan, Korea and most of Central/South America (200-230 VAC):
Wire Phase 1, 2, 3 and Ground
• For Europe and China (380-415 VAC):
Wire Phase 1, 2, 3, Neutral and Ground
a. Loosen the six screws to remove the LPS side panel.
b. Move the AC input line voltage switch in the upper-left corner of the LPS to the left. When
using a 200 VAC supply, see
Configuring ballast settings for 200 VAC operation
on page
20, or to the right when using a 400 VAC supply see
Configuring ballast settings for 400
VAC operation
on page 20.
Caution!
Failure to comply with the following could result in minor or moderate injury.
When connecting the high current lamp leads between the LPS and the igniter, make sure
the black (-) power cable (cathode lead) is securely connected with the washers and lock
washers properly in place and tighten to 175 inch-lbs, 14 ft-lbs or 20Nm at both ends.
Caution!
Failure to comply with the following could result in minor or moderate injury.
Use an appropriately sized strain relief connector with the knockout plate provided to ensure
adequate environmental sealing and to prevent the cable from accidentally being torn out.