8. Using the V FOLD (purple) adjustment knob on the fold mirror, lower the image to expose the
top of the active light area.
9. Using the Focus slider on the integrator, focus the top of the image at the center or slightly left
of center.
10. Using the V FOLD and H FOLD adjustment knobs on the fold mirror, bring the image back up
and fill the active light area.
11. Using the Rotate slider on the integrator, rotate the integrator to reduce shadows in the image.
12. Check the image quality.
13. As required to fill the image, make fine adjustments to the fold mirror, integrator rotation, and
integrator focus.
14. When the correct image quality is achieved, tighten all screws to hold the adjustments:
Adjusting the image
CP2320-RGB Installation and Setup Guide
38