2-22
CP2000-XB Setup Guide
020-100250-02 Rev. 1 (06-2009)
Section 2: Installation & Setup
2.8
Initial Power-up
When the ballast has been properly configured (refer to
Section 2.7 Connecting the Ballast
) and connected to
the projection head, connect its integral line cord to AC. Then:
2.8.1 Set Lamp Type
NOTE
:
Service/installer required.
Explosion hazard. Keep the projection head OFF until you have defined
which lamp type is installed.
Before powering up the projector and igniting the lamp, the installer must define in projector memory which
size lamp is installed; otherwise you risk severely overdriving or underdriving a lamp.
At the TPC, go to the
Admin: Lamp
menu (password required). Enter the size of the lamp currently installed
in the projector (factory default = 2.0 kW). Refer to
Section 3 Basic Operation
if you need help using the TPC
menus. Also record the lamp type on the
Lamp Installed
label.
2.8.2 Set Cable Length
Still in the
Admin: Lamp
menu (see
Figure 2-31
), use the
Cable Length (m)
text box to record the length of
high-voltage DC cables connected between your lamp ballast and projection head. This value regulates the
voltage drop that occurs over distance, and ensures that adequate voltage reaches the lamp. Particularly in a
projector rented for temporary installation, the setting may have to be changed from its last use. Adjustment
range is 2-30m (6½-100 ft.).
2.8.3 Power-up
Power up the
CP2000-XB
system as described in
Section 3.3 Power-up Procedure
.
Figure 2-31 Cable Length
Main
Status
Custom
Advanced
Admin
About
Ballast Cable Length (m)
Save
Содержание CP2000-XB
Страница 1: ...CP2000 XB S E T U P G U I D E 020 100250 02...
Страница 2: ......
Страница 40: ......
Страница 52: ......
Страница 59: ...Section 4 Maintenance CP2000 XB Setup Guide 4 7 020 100250 02 Rev 1 06 2009 Figure 4 4 Replacing the Air Filter...
Страница 66: ......