3.4.4 LCD Error Messages
To receive more information about an error, send the following serial command, where “x” is the first number
in the error message:
HTL+LSOL?x
For instance; if the LCD showed the following:
More information can be retrieved by the following serial command:
HTL+LSOL?3
The projector would then respond with:
For more information about the
HLT
command, see the
Serial Command
(
P/N: 020-100224-XX)
documentation, available on the Christie web site.
Error Alarm 1/1
System Health
3:11 (Critical) Thermal Det: 4
HLT+LSOL!003 “Failed to assign I2C address to
Thermal Sensor. Verify Sensor Configuration
File. Detection Failure for Thermal Sensor.
Check cables and Configuration File.”