Parts list  (con’t) 

Level (1) 

M6 x 12 Safety knobs (2) 

 

5/16" flat washers (6) 

5/16" x 3" Lag bolts (6) 

(used on wood studs only) 

Griplates™ (4) 

Wall plate (1) 

Mounting brackets 

(left & right) 

M6 x 30 Lateral shift 

locking screws (2) 

All of these parts are used to install the mounting bracket.  Make sure that none of these parts are missing before beginning installation. If there 

are parts missing stop the installation and contact Chritie.  

 

M5 x 12 phillip 

screws (4) 

M6 x 12 phillip 

screws (4) 

Adapter plate (1) 

Содержание 38-804785-01

Страница 1: ...Universal flat panel mount I N S T A L L A T I O N M A N U A L www christiedigital com PM 2004 REV 02 ...

Страница 2: ...n general A secured structure wooden stud wall must always support the weight or load of the flat panel Always confirm the center of the wood stud before beginning the installation Do not install in locations where there is vibration movement or danger of impact Failure to do so could result in flat panel cracking or falling from the wall causing damage and injury Do not install near heater firepl...

Страница 3: ...g hardware E M6 x 30 mm Phillip screws F Wood stud G 5 16 x 3 Lag screws and flat washers H Safety knobs Assembly drawing Dimensions are in Inches Fine tune tilt adjustments 1 M5 Phillips screws for fine tension 2 M8 Hex nut coarse tension NOTE The 8 mm hex nut is for your coarse tension adjustment and the 5 mm screws are for your fine tension adjustment A B C D E F G H H G 1 2 ...

Страница 4: ...1 Mounting brackets left right M6 x 30 Lateral shift locking screws 2 All of these parts are used to install the mounting bracket Make sure that none of these parts are missing before beginning installation If there are parts missing stop the installation and contact Chritie M5 x 12 phillip screws 4 M6 x 12 phillip screws 4 Adapter plate 1 ...

Страница 5: ...URE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL DO NOT LAY THE PLASMA ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS THE FLAT PANEL IS HEAVY AND FRAGILE AT LEAST 2 QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL WARNING Proper installation procedure by qualified personnel as ou...

Страница 6: ... phillip head screws Place the grip nipples facing down on the bottom of the mounting bracket and facing up on the top Pre install at least 1 8 of thread into the two 2 M6 x 30 Phillip screws to the right and left mounting brackets See figure 2 and 3 Soft n flat surface Left Right brackets Griplates M5 x 12 Phillip screws Inverted flat panel Soft flat surface Inverted flat panel Left Right bracket...

Страница 7: ...late to the reference line and mark the six 6 lag bolt mounting points through the wall plate slots on the wall Level the wall plate with the reference arrow pointing up to the ceiling See figure 5 Mark the wall and the center of the wood studs Wood stud finder commercially available Mark the six 6 mounting slot openings Wood studs behind the wall structure Center of viewing mark NOTE The wall pla...

Страница 8: ... six 6 pilot holes to the marked wall See figure 6 Level and secure the plate to the wall with the reference arrow facing up to the ceiling Secure the plate using the six 6 5 16 lag bolts and flat washers supplied See figure 7 6 Pilot holes Drill gun ...

Страница 9: ...djustment and lock it by tightening the two 2 M6 x 30 mm Phillips screws found on the bottom of the mounting brackets CAUTION Do not over tighten the M6 screws to the rods See figure 9 Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top and bottom hooks from each bracket to the rods from the wall plates See figure 8 TOP BOTTOM Lateral shift M...

Страница 10: ...ing the flat panel to the wall mount NOTE To remove the display from the wall simply extend the display to its maximum tilt range remove the two 6 mm safety knurl knobs push the flat panel back to it s flat position loosen or remove the two 2 M6 x 30 lateral shift screws and lift the unit of the wall M6 x 12 Safety knobs ...

Страница 11: ... 11 ...

Страница 12: ... 12 PM 2004 www christiedigital com ...