Installation and Operators Instruction Manual
Safety
Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended
precautions and safe operating practices. Keep safety signs in good condition. Replace missing or damaged safety
signs.
Decal Descriptions
Danger: Electrocution Hazard
Disconnect electrical power before inspecting or servicing equipment unless
maintenance instructions specifically state otherwise. Ground all electrical
equipment for safety. All electrical wiring must be done by a qualified electrician
in accordance with local and national electric codes. Ground all non-current
carrying metal parts to guard against electrical shock. With the exception of motor
overload protection, electrical disconnects and over current protection are not
supplied with the equipment.
DANGER : Rotating Fan Blade
Keep Hands away. Disconnect power before servicing. Fan may start
automatically. Do not operate the Fan without the screens in place.
Disregard to the above mentioned
Danger
may cause serious injury including
death.
• Keep all Safety Signs and decals in good condition. Replace damaged or missing
decals.
Planning the layout of the spacing between fans is very
important. Spacing too close together will cause
interference with the flanges. Allow a minimum of 12"
between framed openings of adjacent fans.
Safety
Fan and Fan Framing Dimensions
Slant Wall Fan
Item Description
1
58” [147.32 cm]
2
55” [139.70 cm]
3
50.25” [127.63 cm]
4
8" [20.32 cm]
5
48.5” [123.2 cm]
6
64.5" [163.83 cm]
Spacing Between
Framed Openings 12"
2
Belt drive fan shown
for reference only
2