- 20 -
(2) TCP Server
Function instruction
Function
Description
Local Listen Port Number
Set local I/O port, the range is from0 ~ 65535.
Default setting is
50001
Close Connection When
Remote Idle
The default setting of close connection time is
10
seconds and the
range is from 0 ~ 32768
The value must set to be 0 if you want to keep CYT-133SC connect
with monitoring side or the connection will be off automatically
when remote idle.
Access Password
Make sure the data secure, user must set the code for
management. User must inset the correct password and process
the further procedure after authority.
up to
31
characters
Auto Report I/O Status
Automatically return I/O status
Disable
:
No automatically return I/O Status
State Changed
:
I/O status will be returned automatically when
INPUT changes.
Periodically
:
Set I/O status return automatically every few seconds.
Through
:
I/O status will be returned thru Serial and ETH.