- 10 -
Ⅳ
、
Web Function Instruction
One Page Quick Setup
Function instruction of STATIC IP
Function
Description
IP Address
Set the IP address of the CYT-133SC
,
default setting is
192.168.168.125
Subnet mask
Set the subnet mask of the CYT-133SC
,
default setting is
255.255.255.0
Gateway
Set the gateway of the CYT-133SC
,
default setting is
192.168.168.254
Primary DNS
Set the DNS of the CYT-133SC
,
default setting is
168.95.1.1
Serial Port Mode
Baud Rate
1. Set serial port baud rate, the parameters can be selected
:
1200
、
2400
、
4800
、
9600
、
19200
、
38400
、
57600
、
115200
、
230400 and Others
2. After selecting
Others
, fill custom baud rate into the user defined
3. Default setting is
19200
Serial Server Mode
Connection Mode
There are 5 modes to set into connection mode, such as
:
Real Com
TCP SERVER
TCP CLIENT
UDP
Extend I/O
(
no data conversion
)
Connection Port Number
Set CYT-133SC connection port number, default setting is
50000
Remote Host IP Address
1.Set the remote host IP or domain name
,
default setting is
0.0.0.0
2.
For Client Only
Содержание CYT-133SC