
38
Terminal 7 function
Oil content.
temperature closed/bearing at high temperature and
close/Electrical malfunction normally closed/Motor overload
normally closed/Fan motor overload normally closed/Oil filter
blockage is normally closed./Oil filter clogging is often open/Oil
separator blockage normally closed/Oil separator clogging is often
open/Air filter blockage normally closed/Air filter clogging is often
open/Air port malfunction normally closed/malfunctionofcold
dryerusuallyclosed/motor Frequency converter malfunction often
open/ motor Frequency converter malfunction usually closed/Fan
motor Frequency converter malfunction often open/Fan motor
Frequency converter malfunction normally closed
/
soft starter
failure is often on
Note: the user can input the switch quantity to the required function
according to the need.
Terminal 6
function:
Air filter
Terminal 5
function:
Remote switch
5.1.10 Consumable parameter
Consumable parameters are used to set consumption time.
The user needs to verify the consumables password before viewing or modifying the consumable
parameters.
The main functions and functions are shown in the table below:
Menu
Setting
initial
value
Function description
Oil filter using
time
(
h
)
0000
Theoilfilterhasbeeninuseforacumulativeperiodoftime,
after replacing the new oil filter, manually clear thezero.
Oil separator
using time
(
h
)
0000
Accumulative use time of the oil separator, replace the new
oil separator, manual cleaning.
Air filter using
time
(
h
)
0000
Theairfilteraccumulatesthetimeused,afterreplacingthe
new air filter, manually clear the zero.
Lubricating oil
using time
(
h
)
0000
Thelubricatingoilaccumulateshasusedthetime,afterthe
replacement lubricating oil, manually clears zero.
Grease using
time
(
h
)
0000
Grease has been used for a cumulative period of time, after
the replacement grease, manual clearance.
Oil filter MAX
Using time
(
h
)
2000
1. After the accumulative operating time of the oil filter exceeds the set
value here, the controller warns;
2. Whensetto"0000",preventoilfilterfromwarningfunction.
Содержание Quan Wei
Страница 1: ...TaiWan QuanWei Screw type air compressor Using and Maintenance Instructions ...
Страница 12: ...8 ...
Страница 81: ...77 ...
Страница 82: ...78 8 2 2 QWL 15A 20A 8 2 3 QWL 30A 40A ...
Страница 83: ...79 8 2 4 QWL 50A 60A ...
Страница 84: ...80 8 2 5 QWL 75A 100A ...
Страница 85: ...81 8 2 6 QWL 150A 175A ...
Страница 86: ...82 9 0 Circuit diagram ...
Страница 87: ...83 9 1 MAM 860 880 Circuit diagram 9 2 MAM 890 Circuit diagram ...
Страница 88: ...84 9 3 MAM 6080 Circuit diagram ...
Страница 89: ...85 Screw Air Compressor operation record tale ...