NVF5 Series User Manual Chapter 6 Parameter Function Description
●
Motor Static Auto Tuning
:
It is suitable for occasions where motor and load are
F2.06
Motor NP RPM
1430 rpm
(
0
~
60000
)
rpm
-
F2.07
Motor Stator
Impedance
Depend on
motor type
(
0.001
~
65.535
)
Ω
(
Inverter Power
<=55kW
)
(
0.0001
~
6.5535
)
Ω
(
Inverter Power
>55kW
)
-
F2.08
Motor Rotor
Resistor
Depend on
motor type
(
0.001
~
65.535
)
Ω
(
Inverter Power
<=55kW
)
(
0.0001
~
6.5535
)
Ω
(
Inverter Power
>55kW
)
-
F2.09
Motor Leakage
Inductance
Depend on
motor type
(
0.0
~
655.35
)
mH
(
Inverter Power
<=55kW
)
(
0.001
~
65.535
)
mH
(
Inverter Power
>55kW
)
-
F2.10
Motor Mutual
inductance
Depend on
motor type
(
0.1
~
6553.5
)
mH
(
Inverter Power <=
55kW
)
(
0.01
~
655.35
)
mH
(
Inverter Power >
55kW
)
-
F2.11
Motor no-load
current
Depend on
motor type
0.01A
~
F2.03
(
Inverter Power
<=55kW
)
0.1A
~
F2.03
(
Inverter Power
>55kW
)
-