produce more current and/or voltage than reported at Standard Test Conditions.
Accordingly, the values of Isc and Voc marked on TUV Listed modules should be
multiplied by a factor of 1.25 when determining component voltage ratings,
conductor capacities, fuse sizes and size of
controls connected to the module output.