Chiltern Invadex WISPA 100 Plus Скачать руководство пользователя страница 14

HOIST 

100 Series

Page 12

Issue 

2.0

June 2018

Warranty

Your Chiltern Invadex (UK) Limited Overhead Hoist carries a 12 month warranty from the date of purchase, 

subject to the following :-

1. 

Should you experience any problems with your product within the first 12 months period please 

contact your point of purchase.

2.  Repairs made during the warranty period will be carried out free of charge, provided the product 

has been used strictly in accordance with the guidelines set out in this user guide. 

3.  Our warranty does not cover replacements, adjustments or  repairs which may be required as a 

result of normal wear and tear, wilful or accidental damage, misuse, neglect or any other cause 

which is beyond the control of  Chiltern Invadex (UK) Limited.

4. 

Modifications and repairs made to this product by unauthorised persons will render the warranty void.

5. 

Only parts manufactured or approved by Chiltern Invadex (UK) Limited shall be used to repair this 

product. Use of unauthorised parts will invalidate all warranties and remove all liability from Chiltern 

Invadex (UK) Limited for the safety of this product.

6. 

Chiltern Invadex (UK) Limited shall in no event be liable for any damages, costs or expenses arising 

from any claim made under this warranty (save for any legal liability of Chiltern Invadex (UK) Limited 

for death or personal injury resulting from the company’s negligence in respect of its products).

7. 

This warranty does not affect your statutory consumer rights.

Life Expectancy Statement

Based upon 25 years experience in the manufacture, installation and service of overhead hoists, Chiltern 

Invadex (UK) Ltd confirm a life expectancy of at least 8 - 10 years in relation to ceiling mounted hoists.

The life expectancy of any hoist can be vastly increased or decreased dependant upon the frequency of 

use, the loads applied, correct operation and of course regular servicing and maintenance as detailed 

within this guide.

A full statement of life expectancy can be obtained from Chiltern Invadex.

Содержание WISPA 100 Plus

Страница 1: ...100 Plus models WISPA 100 Plus This user guide contains essential information in relation to safe use and troubleshooting and should be retained with the hoist for reference Unit 6C Thorpe Drive Banbu...

Страница 2: ...Chiltern Invadex hoist has been designed and tested to meet the highest standards of safety Read the safety section of this guide prior to use this is contained on pages 1 2 Intended use 1 Safety cons...

Страница 3: ...oad of the sling or any other lifting accessory where this differs from the hoist the lowest weight must not be exceeded When using the Hoist Ensure when the hoist is in use that the surrounding area...

Страница 4: ...lly or where there is a change in user circumstance property or equipment ISO 10535 recommends that a conveniently placed telephone or alarm system should be provided as a safety control measure As it...

Страница 5: ...Button In event of overload press button to re set Product Identification Label serial number model SWL Carry Spreader Bar Lifting Tape Handset Cable Retaining Socket Emergency Stop Emergency Lower So...

Страница 6: ...ction is controlled by the bottom buttons on the handset The buttons are colour coded with red and green These colours correspond to the red and green direction travel arrows on the underside of the t...

Страница 7: ...gency lowering pull cord Emergency Stop To operate in case of an emergency pull the red cord to switch off the hoist completely E M E R G E N C Y S T O P L O W E R Emergency stop pull cord RESET Reset...

Страница 8: ...en the hoists batteries are in need of charging This is unlikely to happen unless the hoist is used for long periods of time approximately 60 lifts without charging or the hoist has not been properly...

Страница 9: ...at point re installation Information regarding LOLER requirements can be seen at http www hse gov uk pubns hsis4 pdf Maintenance of this equipment should only be conducted by engineers trained and ce...

Страница 10: ...is charging Remove hoist from charging dock and wait for green LED to turn off Powered models only No hoist function No power Ensure mains power is connected check fuse box All models Hoist will not...

Страница 11: ...rack to bottom of carry bar hook at max height is 442mm This is adjustable and should be set by the installer to meet the requirements of the user Typically the carry bar would stop about 300mm from t...

Страница 12: ...ation Notes Important Information Battery Powered Models Where this hoist is to be a replacement unit on an existing track installation the charging unit included in the box MUST be used This hoist is...

Страница 13: ...arry bar can swivel smoothly care should be taken to ensure that the PTFE bearings are flat against the top of the carry bar Place the retainer housing over the lift tape 5 and insert the dowel throug...

Страница 14: ...Invadex UK Limited shall be used to repair this product Use of unauthorised parts will invalidate all warranties and remove all liability from Chiltern Invadex UK Limited for the safety of this produ...

Страница 15: ...s Engineer name Comments Year 2 Date of Service Load tested to kg Serviced by Address Engineer name Comments Year 3 Date of Service Load tested to kg Serviced by Address Engineer name Comments Wispa H...

Страница 16: ...iced by Address Engineer name Comments Year 6 Date of Service Load tested to kg Serviced by Address Engineer name Comments Year 7 Date of Service Load tested to kg Serviced by Address Engineer name Co...

Страница 17: ...ad tested to kg Serviced by Address Engineer name Comments Year 10 Date of Service Load tested to kg Serviced by Address Engineer name Comments In addition to regular service and maintenance a require...

Страница 18: ...The below space can be used to store details of your service contractor if the equipment has been provided by a third party for example the Local Authority this information will be available from the...

Страница 19: ...odels WB WTB WLB WLTB 200L 200LT 200LTR 200LTX 200LTXR 300L 300PT 300PTR 300P 300PR MHWMEHUKEL We hereby certify that the products listed have been designed assessed manufactured labelled and packaged...

Страница 20: ...y disposed of please contact your Local Authority the dealer from where the product was purchased or Chiltern Invadex UK Limited WEEE producer number WEE JD1274RU To request a copy of this guide in la...

Отзывы: