Chapter 4 Configuring Settings (MODE SELECT Mode)
48
3.
Press the ENTER button.
The communication station number check screen appears, showing the current settings.
4.
Press the Up/Down arrow buttons to move to the item you want to set.
5.
Press the ENTER button.
The setting screen appears.
6.
Press the Up/Down arrow buttons to select the desired setting.
7.
Press the ENTER button to determine the setting.
8.
To exit this mode, press the MODE SELECT button to return to normal mode.
4.3 Air Volume-Down Alert Timing Setting Mode
This mode allows for changing the timing for displaying an air volume-down warning (WARN4) as
desired.
1.
Move to the MODE SELECT mode.
2.
Press the Up/Down arrow buttons to move to the air volume-down alert timing setting mode
(“Volume Down ST”).
3.
Press the ENTER button.
The current setting appears.
The default is 50%,
displayed as “3: Down to 50%”.
4.
Press the Up/Down arrow buttons to select a timing between 30 to 70%.
A lower setting causes the air volume-down alert to occur later, and vice versa.
5.
Press the ENTER button to determine the setting.
6.
To exit this mode, press the MODE SELECT button to return to normal mode.
4.4 Supply Voltage Setting Mode (CBA-080AT3-HI-
CE only)
Select your supply voltage: 220 or 230 V.
The air volume-low threshold switches with the selected supply voltage.
1.
Move to the MODE SELECT mode.
2.
Press the Up/Down arrow buttons to move to the supply voltage setting mode (“Supply Voltage”).
3.
Press the ENTER button.
The current setting appears.
The default is 220 V, displayed as “1:220V”.
4.
Press the Up/Down arrow buttons to select 220 V or 230 V.
5.
Press the ENTER button to determine the setting.
6.
To exit this mode, press the MODE SELECT button to return to normal mode.
100% of filter performance is available.
The initially registered value is taken as
100%.
Note: The initial pressure applies when the
suction hose and hood are set in
place.
Differential
pressure lower
Differential
pressure higher
(Default)
Less than 30% of
filter performance
is available.
Filter performance
Setpoint
Lighting occurs earlier.
Lighting occurs later.
Lighting timing can be set to five levels.
To advance the lamp-lighting timing To delay the lamp-lighting timing
Содержание CBA-080AT3-HI