Chapter 4 Configuring Settings (MODE SELECT Mode)
CMN004-005
47
E
nglis
h
Chapter 4 Configuring Settings (MODE
SELECT Mode)
4.1 Screen Transitions in MODE SELECT Mode
To move to the MODE SELECT mode, press the MODE SELECT button during stoppage.
The Up/Down arrow buttons cycle through parameters.
4.2 Communication Format Setting Mode (When
Equipped with Communication Function)
This mode sets the below listed items of serial communication format.
The settings are enabled after the main power switch is turned off and back on.
Item
Setting
Default
Communication station number
1 to 25
1
Baud rate
9600 bps, 19200 bps,
38400 bps, 57600 bps,
115200 bps
9600 bps
Bit length and parity
Bit length = 8 bits, with no parity
Bit length = 8 bits, odd parity
Bit length = 8 bits, even parity
Bit length = 9 bits, with no parity
Bit length = 8 bits, with no parity
Stop bit
Stop bit = 1 bit
Stop bit = 2 bits
Stop bit = 1 bit
1.
Move to the MODE SELECT mode.
2.
Press the Up/Down arrow buttons to move to the communication format setting mode
(“Com Setting”).
[Com Setting]
[Volume Down ST]
[Other Setting]
[Error Data]
Communication format setting mode
(
Page 47)
Air volume-down alert timing setting mode
(
Page 48)
Other setting mode
(
Page 49)
Error history mode
(
[Supply Voltage]
Supply voltage setting mode (CBA-080AT3-HI-CE only)
(