  13

 

 

 

 

5.4 

隔操作と本体操作について 

Remote operation and operation from main body

 

 

遠隔操作で

ON/OFF

する場合は、④と⑧を短絡させておきます。

 

①を短絡

The wire [1] is short-circuited.

ON

 

①を短絡しない

The wire [1] is not short-circuited

OFF

 

(「各線の色と信号について」の表を参照ください)

 

Short-circuit the wires [4] and [8] each other when turning ON and OFF the dust collector by remote 
operation. 
(Refer to the table in “Color and signal of each wire”) 
 

 
 
 
 

 

本体操作で

ON/OFF

して信号を取り出す場合は、④と⑧を短絡させないでください。

 

5.3

各線の色と信号について」の説明に従い、必要な出力信号を取り出して下さい。

 

Do  not  short-circuit  the  wires  [4]  and  [8]  each  other  when  transferring  signals  by  turning  ON  and 
OFF the dust collector from the main body. 
Transfer required output signals in accordance with the explanation in “5.3 Color and signal of each 
wire” 
 
 
 

 

遠隔操作で運転中に能力レベルを変更する場合は、

 

本体

AT

パネルの

ON

を押しながら

Lo, Hi 

で変更してください。

 

Change with Lo/Hi switch pushing the ON switch of main body AT panel when 
you change the suction level during the driving with remote controller. 
 

 

能力レベルの記憶   

The memory of the capacity level 

本体パネルの

OFF

ボタンで能力レベルを記憶しておくと、

 

記憶された能力レベルで運転を開始することができます。

 

但し、主電源で運転停止した場合には、

 

本体

AT

パネルの

ON

ボタン(1回押)で、

OFF

で記憶させた能力レベルを呼び出して下さい。

 

 
When the capacity level is memorized by the OFF switch of AT panel, 
The remote operation is able to start in the same level. 
However, in the case of stopping of the main power, push the ON switch of AT-panel once. 
It is possible to operate at the memorized level by the OFF switch. 
 

 
 
 
 
 
 
 
 
 
 
 

 

ON 

OFF 

①を短絡する

 

The wire [1] is short-circuited. 

①を短絡しない

 

The wire [1] is not short-circuited 

Содержание CBA-080AT-HC

Страница 1: ...lead to a serious accident caused by incorrect handling CAUTION This symbol indicates cautions to assure safe use and actions that may lead to failure caused by incorrect handling Instruction Manual M...

Страница 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Страница 3: ...onfirmation before operation 9 4 5 Operation procedure 10 5 Remote Cable Sold Separately 11 5 1 Electrical circuit diagram 11 5 2 Remote Cable 11 5 3 Color and signal of each wire 12 5 4 Remote operat...

Страница 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Страница 5: ...pair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if...

Страница 6: ...rimary filter Collecting Adsorbing fine dust and fumes Secondary filter Protecting the circuit and the electrical parts Exhaust filter Exhaust treatment 3 Power cable 3m Exhaust port AT AT Panel opera...

Страница 7: ...z CBA 1200AT HC V1 CE 200V 240V 50 60Hz CBA 2000AT HC V1 200V 50 60Hz 10 3m The allowable supply voltage range is 10 The power cable of 3 m with a grounding plug is included 4 2 AT AT panel Filter sat...

Страница 8: ...o Push here to lower gradually suction speed Minimum Lo 40 power Hi 1 1 100 Hi Push here to increase gradually suction speed Maximum Hi 100 power ON OFF ON OFF switch and Main Power supply Light up Re...

Страница 9: ...grounding plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm the items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch...

Страница 10: ...to a proper position Turn ON the MAIN POWER switch and confirm that the power indicator lamp lights Starts the dust collector AT ON Press the ON switch to start the operation 7 Choose operation abili...

Страница 11: ...s put inside a shrinkable tube so that it cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is impossible...

Страница 12: ...panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 1 5V Impedance 4 7...

Страница 13: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Страница 14: ...filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspec...

Страница 15: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Страница 16: ...g operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current generated by a trouble in the internal equi...

Страница 17: ...ing 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fuses are blown out 6 5 Re...

Страница 18: ...IRTEC CO LTD 2009 18 8 Indication of DANGER Labels P r o h i b i t i o n l a b e l P r o h i b i t i o n o f d i s a s s e m b l y W a r n i n g l a b e l H i g h v o l t a g e P r o d u c t n a m e p...

Страница 19: ...Copyright CHIKO AIRTEC CO LTD 2009 19 9 Electrical Circuit Diagram CBA 080AT HC 100V CBA 080AT HC CE 200 240V...

Страница 20: ...Copyright CHIKO AIRTEC CO LTD 2009 20 CBA 1200AT HC CE CBA 500AT HC CE...

Страница 21: ...s CBA 080AT HC V1 250 100 110 Single phase 4 5 50 60 1 5 8 5 54 67 10 0 CBA 080AT HC V1 CE 400 200 240 Single phase 3 0 50 60 1 5 7 8 8 9 200V 240V 54 67 14 5 CBA 500AT HC V1 450 100 110 Single phase...

Страница 22: ...2525 50 V1 CBA 500AT HC V1 FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CBA 500AT HC V1 CE FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CBA 1200AT HC V1 FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CH...

Страница 23: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Отзывы: