08
Can not heating and
cooling.
no refrigerant in system.
Please fill up refrigerant.
The refrigerant leaked.
refill up refrigerant after
checking the
leak source
.
Disconnecting valve dosen’t
turn on.
Please turn on disconnecting
valve.
The system is blocked. For
example the strainer or connect
pipe.
Replace this parts which
blocked.
The compressor failed.
Replace the compressor.
no air from the outlet
find out the cause ,replace the
motor ,capacitor,PCB,or do
other actions
Other
09
Noise and vibration
is existent during
running.
electromagnetic noise from
compressor.
Replace this compressor.
resonance
between
the
compressor and other parts.
Add bumper block or adjust
the position
The indoor and outdoor motor
rusted or electromagnetic noise.
Replace this motor.
The cross flow fan collides with
the slot basis
Reconfigure.
The noise of the refrigerant
moving.
Readjust the position of the
H&L pressure pipe.
The screw of outdoor unit is
loose and caused the noise and
vibration.
crew down this screw.
The bearing of cross flow fan
broke.
Replace the bearing.
The cross flow fan collides with
the foam or sponge
The pipe of outdoor unit contact
with crust
make the pipes well,keep the
suitable space(over 10mm)
The noise come from
synchronous motor, stepper
motor, capacitance,
transformer, reactor.
Replace them
the indoor and outdoor air
circulation channel is clogged,
which generated noise.
Clear the sundries
fan or blower damaged
Replace it
Other
The drain pipe is jammed or
broken.
Clear up the stem or replace a
new pipe.
The installation of evaporator
and water receiving tank is not
in place.
reinstall them
Содержание CS-25V3A-MA114A
Страница 3: ...3 A Summary 1 indoor unit 2 outdoor unit 3 remote controller...
Страница 4: ...4 B Wiring diagram Wiring diagram INDOOR CS 25V3A MA114A CS 35V3A MA114A...
Страница 5: ...5 Wiring diagram OUTDOOR CS 25V3A Y4N CS 35V3A Y4P...
Страница 18: ...18 2 Outdoor CS 25V3A Y4N CS 35V3A Y4P...
Страница 42: ...42 I User s Manual...
Страница 43: ...43 The name of each part and its function...
Страница 44: ...44 Remote controller...
Страница 45: ...45 Use of remote controller Operating machine in selected modes...
Страница 46: ...46...
Страница 47: ...47 Basic principles and performances Features of Heating Operations Methods of maintenance...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...