![Chigo CS-25V3A-MA114A Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/chigo/cs-25v3a-ma114a/cs-25v3a-ma114a_service-manual_2601250011.webp)
11
When multiple indoor units are to be installed in one room (e.g. guest hall,
meeting room, restaurant, etc.), full consideration should be made to the
integral appearance and working performance. They should be installed on the
same level (with the upper as the benchmark) and keep a certain distance, thus
to ensure that the working performance of each indoor unit will not be
affected.
Installation of
Outdoor Unit
1. To install the outdoor unit onto the wall, use the bit of fixed depth to drill
holes according to the selected position, but take care to avoid the wall
clearance. Firstly, mount an expansion bolt 10x100 (mm). Then, use the rope
to move the support outdoors and make a simple fixing. Calibrate the level
with level gauge and mark out the other positioning holes. Then, remove the
support and use the impact drill with fixed depth bit to drill the other fixing
holes of the support. Finally, fix the support onto the exterior wall. 6 pcs
required for model 61 or lower, and 8 pcs required for the model over 61.
Note: The expansion tube of the expansion screw must be fully punched into
the wall.
1. Move the outdoor unit out of the room and put it onto the support with care.
Fix with 4 bolts Ø10mm. (Note: The installation people working on the 2
nd
floor or higher must wear safety belt. The outdoor unit must be tied securely
with rope before it can be put outdoors. Take anti-fall measures to avoid
accident.
)
2. The outdoor unit is directly onto the ground (e.g. balcony, roof platform,
outdoor ground of the 1
st
floor, and other platforms that can accommodate the
outdoor unit adequately). According to the size of chassis mounting hole,
select proper expansion screws to fix tightly. The height difference between
indoor and outdoor unit shall not be higher than 5m; otherwise it might cause
difficulty to oil return and affect the service performance.
Required distance of the space around the outdoor unit (unit: mm)
1. With obstacle above
Over 300
Ov
er
6
0
0
2. With front side
(outlet port) open
Ov
er
3
00
Over
300
Over
600
3. With obstacles only on
front side (outlet port)
Ov
er
2
00
Repair space
Keep repair space on the front side of the
unit, as shown below.
Over
300
Over
500
Ov
er
5
00
Repair space
4. With obstacle on both front side and back side
Ov
er
3
00
Ov
er
20
00
5. With obstacles on four sides
Though the upper side is open but
there are obstacles on four sides,
the machine cannot be installed
there.
Keep two sides open at least.
Indoor unit
Outdoor
unit
Содержание CS-25V3A-MA114A
Страница 3: ...3 A Summary 1 indoor unit 2 outdoor unit 3 remote controller...
Страница 4: ...4 B Wiring diagram Wiring diagram INDOOR CS 25V3A MA114A CS 35V3A MA114A...
Страница 5: ...5 Wiring diagram OUTDOOR CS 25V3A Y4N CS 35V3A Y4P...
Страница 18: ...18 2 Outdoor CS 25V3A Y4N CS 35V3A Y4P...
Страница 42: ...42 I User s Manual...
Страница 43: ...43 The name of each part and its function...
Страница 44: ...44 Remote controller...
Страница 45: ...45 Use of remote controller Operating machine in selected modes...
Страница 46: ...46...
Страница 47: ...47 Basic principles and performances Features of Heating Operations Methods of maintenance...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...