Chigo CMV-MINI Скачать руководство пользователя страница 16

12

Starting time setting

Dialing Content

Switch No.

SW3

Dialing Illustration

Set Value

1

2

3

O N D P

4

1

2

3

O N D P

4

Starting time 12 minutes

Starting time 3 minutes

1

2

ON DP

1

2

ON DP

1

2

ON DP

1

2

O N D P

1

2

ON DP

3

1

2

ON DP

3

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

Address setting

Capacity setting

SW6

SW4

+

SW5

0

-

15

16

-

31

32

-

47

48

-

63

8k

W

10.

5

k

W

Table 5-2 10.5kw Dialing  

Table 5-3  14/16 kw  Dialing

No.

Current frequency / number of indoor units (standby 

display)

Capacity of outdoor unit 

Total capacity need of indoor unit

Total capacity needs of corrected host 

Operation mode (0-4)

Actual running ability of outdoor unit

Gears of fan (0-7)

T2 / T2 B average temperature

T3 temperature of outdoor condenser

T4 environmental temperature

T5 exhaust temperature

Opening of electronic expansion valve = 

spot-check display value × 8

AC transformer current

Input AC voltage

Secondary side current

Secondary side current - (spot-check display × 4)

Number of indoor 

Number of working 

Last fault protection code (no fault display -)

Control parameters (only for use of development personnel)

Control parameters (only for use of development personnel)

Spot-check Content

1

2

3

4

5

6

7

8

9

10

No.

Spot-check Content

12

13

14

15

16

17

18

19

20

21

11

5.4 Outdoor unit spot-check instructions

Table 5-4 Outdoor Unit Spot-check Instructions

Definition of operation mode: 0-Shutdown/air supply; 2-Cooling; 3-Heating; 4-Forced cooling.

Table 5-5 Outdoor Unit Fault Code

E2

E4

E6

E9

E10

H0

H1

Fault Code

Fault Contents

Communication fault between the outdoor unit and the host

Environmental temperature sensor fault

Condenser pipe temperature sensor fault

AC over-voltage / under-voltage protection

EEPROM fault

Communication fault of 0513 and DSP

Communication fault of 0513 and 052 7

E1

Outdoor unit phase-sequence fault

20-minute break at first or 2-minute break later 

Remark

Starting time setting

Dialing Content

Switch No.

SW3

Dialing Illustration

Set Value

Starting time 12 minutes

Starting time 3 minutes

1

2

ON DP

1

2

ON DP

1

2

ON DP

1

2

O N D P

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

0

1

2 3

4 5

6

7

8

9

A

B

C

D

E

F

Address setting

Capacity setting

SW6

SW4

+

SW5

0

-

15

16

-

31

32

-

47

48

-

63

12k

W

1

4k

W

1

ON DP

1

ON DP

1

6k

W

1

2

ON DP

3

1

2

ON DP

3

1

2

ON DP

3

1

8

k

W

1

2

ON DP

3

Содержание CMV-MINI

Страница 1: ...ppearance of your air conditioner is different from that of the air conditioner in the Manual it will not affect its operation and use Please read this Manual before use carefully and keep this Manual...

Страница 2: ......

Страница 3: ...Table of Contents 1 Safety Precaution 1 2 Key Points for Construction Inspection 1 3 Installation of Outdoor Unit 2 4 Installation of Connecting Pipe 4 5 Electrical Wiring 10 6 Trial Run 14...

Страница 4: ......

Страница 5: ...ction Inspection 2 1 Arrival of goods and open case inspection 1 When receiving the machine check if there is any damage in transportation If any surface or internal damage is found please inform the...

Страница 6: ...installation and maintenance 2 No barrier at the air inlet and the air outlet and away from strong wind 3 Dry and ventilated 4 The flat supporting surface is able to bear the weight of the outdoor uni...

Страница 7: ...o be careful to hoist the machine 4 Don t hold the suction inlet of the housing or it will be deformed 3 5 Installation and maintenance space of outdoor unit 1 Provide a firm and adequate foundation t...

Страница 8: ...nnecting pipe Threaded connection Gas side connecting pipe Liquid side connecting pipe Welding 4 Installation of Connecting Pipe 4 1 Refrigerant pipe 1 Flaring Use a pipe cutter to cut the refrigerant...

Страница 9: ...efrigeration system When fastening the nut too strong force will damage the flared socket but too weak force will result in leakage Please refer to the tightening torque in the table above to fasten t...

Страница 10: ...e diameter Pipe Capacity of Outdoor Unit kW Dimension of Main Pipe mm L 30m 1 L 30m 1 Liquid pipe 9 52 Liquid pipe 15 88 Liquid pipe 9 52 Liquid pipe 15 88 10 5 9 52 15 88 9 52 19 05 14 16 Table 4 3 D...

Страница 11: ...7...

Страница 12: ...refrigerant pipe is installed and connected to the indoor unit and before the connecting pipes between the indoor and outdoor units are connected to the valves of the outdoor units refill the nitrogen...

Страница 13: ...t keep the vacuum pump on for 1 2h 4 6 Refilling volume of refrigerant The refilling volume of refrigerant R410A is calculated according to the diameter and length of the pipe at the liquid side of th...

Страница 14: ...tem of the indoor unit shall be incorporated into the same system To reduce the interference the indoor and outdoor communication cables shall use two core or three core shielded twisted pair cables i...

Страница 15: ...shielding net shall be connected to the ground Never connect the power line strong current to the terminal block of the signal line weak current Otherwise the power board will be burnt out 5 2 Wiring...

Страница 16: ...play Control parameters only for use of development personnel Control parameters only for use of development personnel Spot check Content 1 2 3 4 5 6 7 8 9 10 No Spot check Content 12 13 14 15 16 17 1...

Страница 17: ...utes 12 14 16and 18kW are effective 8 and 10kw have no such faults Display H6 for 3 times within 100 minutes 6 Trial Run 6 1 Inspection and confirmation before debugging 1 Check and make sure the refr...

Страница 18: ...olume of refrigerant before delivery see the nameplate refilling volume of refrigerant corresponding to the length of pipe 3 B Calculate the indoor volume B m by the minimum volume Critical concentrat...

Страница 19: ......

Страница 20: ...ong CHIGO Heating Ventilation Equipment CO LTD Address Chigo Industrial District Nanhai Foshan Guangdong China P C 528244 Tel 86 757 8836905 Fax 86 757 88783793 4006 757 555 Hotline Web http www chigo...

Отзывы: