background image

Installation Instructions

TS110SU/TS118SU

7

Install Main Assembly to Wall

-

Hollow

Concrete Block, Poured Concrete or Clay
Brick

WARNING:

Failure to provide adequate structural strength

for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component. Do NOT install to a concrete wall of any kind that
has a drywall covering!

WARNING:

INSTALLING THE TS110SU/TS118SU INTO

UNDERRATED OR DAMAGED CONCRETE CAN LEAD TO
SERIOUS INJURY OR DAMAGE TO PRODUCT! Never
install the TS110SU/TS118SU into cracked, chipped or
flaking concrete.

1.

Determine mounting location.

2.

Measure 2 5/8" above desired center line if mounting
TS110SU or 1" below desired center line if mounting
TS118SU and mark a hole at desired mounting location.
(See Figure 4)

IMPORTANT ! :

Use a level to make sure main assembly

(H) is level when mounted to the wall!

IMPORTANT ! :

The TS110SU/TS118SU mounts are

designed to be mounted to an 8" concrete, 8"x8"x16" concrete
block or clay brick wall.

3.

Drill one 8mm hole at location marked in Step 2. (See Figure
4)

Figure 4

4.

Install one concrete anchor (F) into drilled hole. (See Figure
5)

5.

Install one 1/4 x 2 1/2" lag bolt (E) into concrete anchor (F),
leaving bolt hanging out 1/2" from the wall. (See Figure 5)

6.

Hang main assembly (H) onto lag bolt (E) by latching key-
shaped hole over top of bolt. (See Figure 5)

Figure 5

7.

Mark hole at lower mounting hole location. (See Figure 6)

8.

Remove main assembly (H) from wall.

9.

Drill 8mm hole at marked location. (See Figure 6)

10. Install remaining concrete anchor (F) into drilled hole. (See

Figure 6)

11. Hang main assembly (H) back onto wall.

12. Install remaining 1/4 x 2 1/2" lag bolt (E) into concrete

anchor (F) to secure mount to wall. (See Figure 6)

13. Tighten both lag bolts (E) to fully secure mount to wall.

Figure 6

2

3

8mm

screen

center

2 5/8"

TS118SU

TS110SU

screen

center

1"

(E)

6

1/2"

5

4

(F)

(E)

(F)

(TS110SU shown)

(E)

12

7

9

10

(F)

(TS110SU shown)

Содержание Thinstall TS110SU

Страница 1: ...Instalação Istruzioni di installazione Installatie instructies Instructions d installation TS110SU TS118SU Small Thinstall Swing Arm Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TS110SU TS118SU ...

Страница 2: ...te this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly ass...

Страница 3: ...ENSION FROM WALL 12 0 MAX 7 37 187 1 9 09 230 9 08 FACEPLATE THICKNESS 90 PAN LEFT RIGHT 6 24 158 6 27 6 7 2 62 66 5 SCREEN CENTER TO TOP LAG BOLT 9 51 241 6 6 43 163 3 SCREEN CENTER COMPATIBLE MOUNTING PATTERNS INCLUDE 75 X 75 100 X 100 200 X 100 200 X 200 1 50 38 MIN DISTANCE FROM WALL 18 01 457 5 MAX EXTENSION FROM WALL 12 0 MAX TILT 6 05 153 7 2 49 63 2 1 06 26 9 9 09 230 9 PAN LEFT RIGHT 27 6...

Страница 4: ...sel Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perf...

Страница 5: ... 1mm 8mm concrete concrete only H 1 D2 4 A B C D A1 4 M4x12mm A2 4 M4x16mm A3 4 M4x25mm B1 4 M5x12mm B2 4 M5x16mm B3 4 M5x25mm C1 4 M6x12mm C2 4 M6x16mm C3 4 M6x25mm M5 J 1 main assembly E 2 1 4 x 2 1 2 F 2 concrete anchor G 1 3 16 D3 8 1 4 D1 4 M4 wall cover H 1 main assembly J 1 wall cover TS118SU TS110SU ...

Страница 6: ...gure 1 IMPORTANT Use a level to make sure main assembly H is level when mounted to the wall IMPORTANT The TS110SU TS118SU mounts are designed to be mounted to a 2 x 4 wood studs 16 on center wall 3 Drill one 1 8 hole at location marked in Step 2 See Figure 1 Figure 1 4 Install one 1 4 x 2 1 2 lag bolt E into hole leaving screw hanging out 1 2 from the wall See Figure 2 5 Hang main assembly H onto ...

Страница 7: ...unting location See Figure 4 IMPORTANT Use a level to make sure main assembly H is level when mounted to the wall IMPORTANT The TS110SU TS118SU mounts are designed to be mounted to an 8 concrete 8 x8 x16 concrete block or clay brick wall 3 Drill one 8mm hole at location marked in Step 2 See Figure 4 Figure 4 4 Install one concrete anchor F into drilled hole See Figure 5 5 Install one 1 4 x 2 1 2 l...

Страница 8: ...elected diameter A1 B1 or C1 into display mounting hole Do NOT fully thread screw into hole at this time 3 Install two selected screws A C into upper two holes on back of display See Figure 7 IMPORTANT If using M4 or M5 screws A or B washer hardware D1 or D2 should be used to ensure tight fit into the faceplate holes IMPORTANT For recessed mounting holes or to gain extra space 1 4 spacers D3 may b...

Страница 9: ...enter tabs and lifting covers to the open position See Figure 11 Figure 11 3 Route cables on top of upper arm See Figure 12 NOTE Cable ties not included may be used to secure cables to back of faceplate using cable tie holes on either side of faceplate 4 Optional Use cable ties not included to secure cables to upper arms by threading ties around cable and through cable tie holes inside the covers ...

Страница 10: ...iction adjustment screw on each side of the pitch mechanism that must be adjusted evenly in order to properly adjust tension Figure 13 Arm Tension Adjustment 1 Use 3 16 hex key T to adjust arm tension at any of the tension adjustment points See Figure 14 or See Figure 15 Figure 14 Figure 15 side view of TS110SU arm tension adjustment points TS110SU arm tension adjustment points TS118SU ...

Страница 11: ...Installation Instructions TS110SU TS118SU 11 ...

Страница 12: ...nklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief Manufacturing a products divi sion of Milestone AV Technologies 8832 002076 REV 03 2012 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 05 12 ...

Отзывы: