I N S T A L L A T I O N       I N S T R U C T I O N S  

STRUCTURAL CEILING PLATE WITH FLEX JOINTS 

CMA-345

 

The CMA-345, Structural Ceiling Plate with Flex Joint minimizes the transfer of shock and extreme 
vibration from the plate to the equipment.  By using any length of standard 1 1/2” NPT pipe threaded on both 
ends, or extension column, you can extend the height capabilities to meet your needs. 

WARNING:  IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY!

  

When mounting Chief Manufacturing accessories, the structural system and mounting method 

MUST

 be capable of supporting 5 times the combined weight of the total installation. 

The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg). 

Unpack and check contents: 
(1) Structural Ceiling Plate CMA-345 

(1)  5/16-18 Allen Set Screw 

(1) 5/32” Allen Wrench 

INSTALLATION INSTRUCTIONS 

1.  Secure ceiling plate to structural member. 

(SEE WARNING ABOVE)

 Bolt hole spacing is shown on 

Figure 1. 

2.  Thread your standard NPT 1 1/2” pipe or extension column into ceiling plate, tighten securely. 
3.  . Install and securely tighten the 5/16 – 18 socket set screw. 

3.13

6.25

3.25

6.50

6X %%c.38

3.36

7.25

7.25

1 1/2" NPT

 

Figure 1. CMA-345 Dimensions 