Display Installation

WARNING:  

IMPROPER INSTALLATION CAN LEAD TO 

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY 
OR DAMAGE TO EQUIPMENT. Displays can weigh in 
excess of 40 lbs (18.1kg). ALWAYS use two people and 
proper lifting techniques when installing display.

WARNING:  

IMPROPER INSTALLATION CAN LEAD TO 

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY 
OR DAMAGE TO EQUIPMENT. Make sure mounting buttons 
on display are properly seated in mounting holes in faceplate.

To install display:
1.

Move mount faceplate to extended position by grasping 

faceplate and pulling outward away from wall.                    

(See Figure 8)

2.

While supporting both sides of display, align four mounting 

buttons on display or interface bracket with four mounting 

holes in faceplate. (See Figure 8)

3.

Lower display into place listening for audible "click" to 

ensure recessed area of mounting buttons are properly 

seated in lower area of mounting holes and "click lock" 

mechanism has engaged. (See Figure 8) and                      

(See Figure 9)

Figure 8

NOTE:   

Holes are provided in the faceplate for use with a 

padlock or similar locking device, if desired. In addition, 
the pin and nut may be removed from the upper holes 
and moved to the lower holes for use as a more 
permanent locking device. (See Figure 9)

Figure 9

CABLE MANAGEMENT

WARNING:  

IMPROPER INSTALLATION CAN LEAD TO 

SERIOUS PERSONAL INJURY OR DAMAGE TO 
EQUIPMENT! Make sure cables do not run through pinch 
points.

1.

Loosen front and rear cable clamps on top arm.                      

(See Figure 10)

2.

Thread cable ties (K) under cable clamps and secure 

clamps to top arm. (See Figure 10)

3.

Route power/audio/video cables through the cable channel 

in top arm (See Figure 10), allowing sufficient slack in 

cables for left/Right movement of display and swing arm 

and also swing arm extension and retraction.

4.

Secure cables to top arm using two cable ties (K).

5.

Repeat steps 1 through 4 for lower arm.

WARNING:  

IMPROPER INSTALLATION CAN LEAD TO 

SERIOUS PERSONAL INJURY OR DAMAGE TO 
EQUIPMENT! DO NOT route cables through holes in 
faceplate.

1

3

4

 

5

4

Remove pin

and nuts and 

move to lower holes.

A padlock or bolt may

be placed through latch

holes

Содержание PWRSKU

Страница 1: ...es de Instalação Istruzioni di installazione Installatie instructies Instructions d installation Large Flat Panel Steel Stud Wall Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description PWRSKU ...

Страница 2: ...structions provided WARNING Failure to provide adequate structural strength for the installation of this kit can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this mount is attached can support five times the combined weight of all equipment WARNING Exceeding the weight capacity can result in serious personal injur...

Страница 3: ...HE MOUNT SEE PSB XXXX DRAWING ALSO 3 93 100 533 21 00 62 279 10 99 27 00 686 635 25 00 432 17 00 25 1 00 302 11 90 493 19 40 228 8 96 2 43 4 74 120 INCHES THE FOLLOWING FORMAT Mounting Pattern ALL MEASUREMENTS ARE IN MILLIMETERS PRODUCT FEATURES WEIGHT CAPACITY 125 LBS HEIGHT ADJUSTMENT 0 TILT ROLL YAW 5 15 2 5 0 25 03 636 3 50 89 Extended Tilted Down Tilted Up Unit Depth Retracted Tilt Adjustment...

Страница 4: ...PWRSKU Installation Instructions 4 TOGGLERĂ x1 I M 1 4 1 2 Ø13mm B 8 E 2 C 8 D 8 1 4 20 x 1 3 4 A 1 G 4 F 1 H 1 J 2 1 4 20 SNAPTOGGLE BB K 12 TOOLS REQUIRED FOR INSTALLATION AND PARTS ...

Страница 5: ...uld be mounted to the same stud Figure 1 to a minimum of one stud left and right of the stud s Stud type and structural strength must conform to the North American Drywall 1 2 100 lbs max or Drywall Thickness Display Mount Installation Location FRONT Both Sides of Stud Must be centered on stud There must be a minimum of 1 7 8 48mm clearance inside wall 16 or 24 on center Studs If back side of wall...

Страница 6: ...om wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 4 8 Slide plastic cap on anchor D towards wall until flange of cap is flush with wall See Figure 4 Figure 4 9 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 5 10 Repeat steps 6 through 9 for each moun...

Страница 7: ...nd positioning as shown in figure below See Figure 7 2 Lower bottom of upper wall channel cover E and tap firmly across bottom of channel to lock in place as shown in figure below See Figure 7 3 Install R H and L H end caps G by aligning tabs on end caps with slots in wall channel and sliding tabs into channel until end cap is flush with wall channel cover cover E 4 Repeat steps 4 through 6 above ...

Страница 8: ... engaged See Figure 8 and See Figure 9 Figure 8 NOTE Holes are provided in the faceplate for use with a padlock or similar locking device if desired In addition the pin and nut may be removed from the upper holes and moved to the lower holes for use as a more permanent locking device See Figure 9 Figure 9 CABLE MANAGEMENT WARNING IMPROPER INSTALLATION CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE ...

Страница 9: ...ntal alignment Roll of the display to be adjusted up to 2 deg right or left to level the display after installing To adjust Roll 1 Loosen the roll tension adjustment nut located on the back side of the faceplate assembly See Figure 11 2 Level display 3 Tighten roll tension adjustment nut See Figure 11 Figure 11 2 1 3 ...

Страница 10: ...ee Figure 12 NOTE The display may need to be repositioned in order to gain access to the tension adjustment screw s 3 Check swing arm tension If desired tension is present tension adjustment is complete If additional tension adjustment is required repeat steps 2 thru 4 until desired tension is achieved NOTE If changing from a smaller display to a larger display may be necessary to increase swing a...

Страница 11: ...Installation Instructions PWRSKU 11 ...

Страница 12: ...e A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 Chief Manufacturing a division of Milestone AV Technologies 8832 000224 RevD 2008 Milestone AV Technologies www chiefmfg com 08 08 ...

Отзывы: