background image

Installation Instructions

 TIL1X2PT / TIL1X3PT / TIL1X4PT / TILVABPT

25

DIMENSIONS...cont’d

CREATED WITH THE FOLLOWING COMPONENTS

5-TIL1X3PT

5-TIL1X2PT

5-TILVABPT

DIMENSIONS:        INCHES
                         [MILLIMETERS]

TiLED 5X5 CONFIGURATION

Содержание PT Series

Страница 1: ... TIL1X4PT TILVABPT Accessory PT Series LED Wall Mounts Accessory Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT ...

Страница 2: ...serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all mounting systems are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this mounting system can result in serious personal injury or damage to equipment It is the installer s responsibility to mak...

Страница 3: ...abelschlüssel Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill...

Страница 4: ...2 Level 4 ft long Small level 3 8 1 2 Ratchet with 1 2 drive String 1 deep well socket Mounting Hardware Kit Qty per bag N 2 Vertical connector P 1 TIL1X2PT Q 1 TIL1X3PT R 1 TIL1X4PT OR OR TiLEDPT Hardware Kit Qty per bag Adjustment washers B 4 UX10x60R anchor C 4 5 16 x 2 1 2 D 4 5 16 E 2 1 4 20 F 4 1 4 G 6 10 x 1 2 H 2 1 4 20 x 4 1 2 J 8 10 24 x 1 Mounting Button Kit Qty per bag K 4 M5x20mm L 4 ...

Страница 5: ...ching mounts out from the center to the left and right ends Installation on smaller walls may be easier if started at the left side of the video wall using the following instructions 1 Determine location for the top left corner of the LED wall See Figure 2 2 Make a mark 7 below the planned top left corner of the LED wall See Figure 2 3 Using a level mark a horizontal line across width of LED wall ...

Страница 6: ... of 5 8 or a 3 4 thickness plywood backed steel stud wall covered with drywall having a maximum thickness of 5 8 Table 1 Fastener Information 1 Hold furthest left top wall mount against wall ensuring that mounting slot is lined up with center line marked on the wall in Determining Installation Site section Double check with a level See Figure 6 2 Mark mounting holes in two top mounting slots along...

Страница 7: ...en to wall See Figure 7 6 Place a level across front of the mount at bottom of teardrop slots See Figure 8 7 Check the level of the mount at the teardrop slots See Figure 8 Figure 8 8 Slide the left A Left and right A Right adjustment washers into place behind the partially installed lag screws See Figure 9 Figure 9 9 Check the level of the mount at the bottom of the teardrop slots See Figure 10 1...

Страница 8: ... apart on center See Figure 6 4 Drill two pilot holes same size as those drilled for first mount at each marked location and use same fasteners used on the first mount 5 Partially install two fasteners into wall but do NOT completely tighten to wall 6 Hang wall mount aligning upper mounting slots over fasteners and adjust side to side for proper location 7 Install two 1 4 20 x 4 1 2 hex head bolts...

Страница 9: ...m row of the installed mounts referencing the LED screen installation manual for specific instructions during the mount installation checking alignment before removing the housings and then continuing the installation IMPORTANT Continually recheck the alignment and overall flatness of the wall mounts during the installation process 15 Continue the installation process until all wall mounts are att...

Страница 10: ...15 19 Run a string between the self tapping screws installed in Step 18 to assist with alignment across long sections of mounts See Figure 15 Figure 15 String to assist 19 Multiple TIL1X3PT shown as example G 18 for using string to assist with alignment TIL1X4PT shown as example Circles indicate tapping screw hole locations for attaching string to assist with alignment of mounts 18 with alignment ...

Страница 11: ...nting buttons are against the tapping screws and to allow clearance for installation of the second column 5 After the second column of housings is installed push to the left until the first and second columns of housings are touching 6 Repeat until all housings are installed NOTE The tapping screws assist in centering the housings on the mounts 7 OPTIONAL Remove tapping screws if housings need to ...

Страница 12: ...loosen or tighten the leveling feet adjust bolt using a 1 socket and T handle driver to assist in leveling the LED housings across the various wall mounts until plumb See Figure 18 IMPORTANT It is best to make adjustments in small increments to prevent any binding or torquing of the mounts Be sure to adjust the depth evenly for both sides of the mounts CAUTION Over torquing may cause damage Do NOT...

Страница 13: ...ange head lag bolt C and one 5 16 washer D through product into each anchor in wall See Figure 20 3 Repeat for remaining pilot holes Figure 20 Steel Stud IMPORTANT See Site Requirements for Steel Stud Installation section before proceeding with Steel Studs installation to ensure installation site meets requirements The drywall must have a minimum thickness of 1 2 1 Hold metal channel on anchor fla...

Страница 14: ...rew through 1 4 washer corresponding mounting hole in wall bracket and into anchor and tighten until flush against wall bracket DO NOT over tighten See Figure 24 Plastic straps Drywall Anchor metal channel Plastic cap 4 Steel stud side view if present Figure 24 Drywall Anchor metal channel Phillips 6 Steel stud Washer side view Wall bracket if present screw ...

Страница 15: ...talled and right of the stud s being used to install the mount Drywall must be secured to studs with screws a maximum of 12 305mm apart down center of stud Steel Stud 2 x 4 25ga minimum Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members Both Sides of Stud 362 S 125 18 C Shaped S Stud Section Plywood 3 4 minimum ...

Страница 16: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 16 Configuration Examples The following are just two examples of the many configurations which are possible with the PT Series wall mounts ...

Страница 17: ...TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT Installation Instructions 17 ...

Страница 18: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 18 DIMENSIONS TIL1X2PT DIMENSIONS INCHES MILLIMETERS ...

Страница 19: ...TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT Installation Instructions 19 DIMENSIONS cont d SLOTS TIL1X3PT DIMENSIONS INCHES MILLIMETERS ...

Страница 20: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 20 DIMENSIONS cont d SLOTS DIMENSIONS INCHES MILLIMETERS TIL1X4PT ...

Страница 21: ...1X3PT TIL1X4PT TILVABPT Installation Instructions 21 DIMENSIONS cont d 3 50 88 9 0 81 20 6 1 25 31 8 KIT INCLUDES 2 BRACKETS TILVABPT DIMENSIONS INCHES MILLIMETERS B DETAIL B SCALE 1 2 A 0 38 9 5 DETAIL A SCALE 1 2 ...

Страница 22: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 22 DIMENSIONS cont d TiLED 3X3 CONFIGURATION DIMENSIONS INCHES MILLIMETERS ...

Страница 23: ...1X2PT TIL1X3PT TIL1X4PT TILVABPT Installation Instructions 23 DIMENSIONS cont d A SCALE 1 3 CREATED USING FOUR TIL1X4PT TiLED 4X4 CONFIGURATION DIMENSIONS INCHES MILLIMETERS TiLED 3X3 CONFIGURATION cont d ...

Страница 24: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 24 DIMENSIONS cont d A SCALE 1 3 TiLED 4X4 CONFIGURATION cont d DIMENSIONS INCHES MILLIMETERS ...

Страница 25: ...tallation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 25 DIMENSIONS cont d CREATED WITH THE FOLLOWING COMPONENTS 5 TIL1X3PT 5 TIL1X2PT 5 TILVABPT DIMENSIONS INCHES MILLIMETERS TiLED 5X5 CONFIGURATION ...

Страница 26: ...TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT Installation Instructions 26 ...

Страница 27: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 27 ...

Страница 28: ...00 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 8800 003148 Rev02 2019 Legrand AV www legrandav com 02 2020 ...