13
2-10. Maintenance
(1) The machine and torch must be kept away from dust, humidity, and rain.
(2) Avoid vibration when moving the machine.
(3) Do not connect machine cables in reverse.
(4) Clean off dust, debris, and verify screw tension to keep the machine in operating condition.
(5) Turn off the machine when not in use.
(6) Do not immediately adjust the capacitor to high voltage. Adjustments can be made after significant use (more
than 6 months).
Turn the charge voltage adjustment to the limit. From 30V, begin to increase the voltage slowly. Increase the
maximum voltage to 180V. The adjustment process from 30-180V take about 10 minutes. After the 10 minute
adjustment, turn off the power switch and then turn on again. Then adjust to the desirable voltage.
2-11. Selecting stud screws
Metal: soft steel, stainless steel, aluminum, titanium (Ti), brass ,copper
(1) Model
F
S
TP
Total Length
Total Length
Thread
Diameter
Screw
Diameter
Total Length
(2) Dimension outside thread-------- thread diameter * total length
internal thread --------screw diameter * total length - thread diameter
3. Trouble shooting
No power
1. Check the source power
2. Check the input cable
3. Check the main switch
4. Contact the manufacturer
No weld
1. Check the output cable (torch & ground)
2. Check the connection & gun torch
3. Check power fuse
4. Check transformer (overheated)
5. Contact the manufacturer
Fan is not working
1. Check for power at the fan
2. Check the fan (clean debris from fan)
3. Contact the manufacturer
CD stud mode
Cannot adjust the
output voltage
Contact the manufacturer