CMS445P2
Installation Instructions
8
2.
Remove one Phillips head screws holding outlet box to
outer housing and loosen the other one. (See Figure 8)
Figure 8
3.
Rotate outlet box counter-clockwise until it is free to be
removed from housing. (See Figure 8)
4.
Remove outlet box from housing. (See Figure 8)
5.
Use #10-32 x 3/8" flange screw (E) and flathead screwdriver
to attach grounding wire (F) to housing at hole near earthing
symbol. (See Figure 9)
Figure 9
6.
Remove four Phillips screws from ring attached to outlet
box. (See Figure 10)
7.
Remove and discard ring from outlet box. (See Figure 10)
Figure 10
8.
Wire the outlet box as required. Refer to Table 1 and Table 2
on page 6) for input and output specifications. (See Figure 4)
9.
Lower outlet box into the mud ring (B) and attach two screw
spacers (C) inside the mud ring on either side of outlet box
using four 06-32 x 1/4" Phillips pan head screws (D). (See
Figure 11)
10. Lower housing from above CMS445P2, install outlet box
assembly up into housing, and rotate clockwise into place.
(See Figure 11) and (See Figure )
Figure 11
2
x 2
3
4
outlet box
(view from below)
(E)
5
(F)
earthing symbol
6
x 4
Ring
7
Above-Tile Installation Only
(D) x 4
(C) x 2
(B)
Outlet
box
Housing
CMS445P2
9
9
10
Содержание CMS445P2
Страница 10: ...CMS445P2 Installation Instructions 10...
Страница 11: ...Installation Instructions CMS445P2 11...