background image

Содержание CMA440

Страница 1: ...AUTION To prevent damage to the Kit which could affect or void the Factory warranty and to the equipment that will be attached to it thoroughly study all instructions and illustrations before you begi...

Страница 2: ......

Страница 3: ...responsible for verifying that the ceiling to which the CMA 440 s reinforcing plate is anchored will safely support the combined load of all attached components or other equipment WARNING The weight o...

Страница 4: ...3 Installation Instructions CMA 440 Light Weight Suspended Ceiling Kit DIMENSIONAL DRAWING...

Страница 5: ...ark the mounting hole where the pipe will protrude from the ceiling 5 Install the ceiling tile and ceiling tray and clamp the ceiling tray to the ceiling track 6 If necessary remove outlet box knockou...

Страница 6: ...ght and twist it around itself at least four times No additional anchor is required see Figure 6 Anchoring Procedure 1 Cut the 20 ft 6 1 m tie wire into four pieces of equal length WARNING Make sure t...

Страница 7: ...anchor Pass each end through the holes in the ceiling plate reinforce ments and join them with the cable clamp Do not tighten yet 2 Attach all components and equipment to the reinforcing plate refer...

Страница 8: ...5 8 4 30 RING escutcheon 1 40 TURNBUCKLE 1 4 20 with hook and loop 4 50 SCREW lag eye 4 60 ANCHOR concrete 4 70 CLAMP wire rope for 1 8 wire 2 80 WIRE 14 gage 20 ft 6 1 m 1 90 CABLE 1 8 10 ft 3 m 1 1...