Hang Ceiling Tray

WARNING:  Improper installation can cause serious per-
sonal injury!  Make sure that the ceiling structural mem-
bers can support a redundant weight factor

five times

 the

total weight of the equipment you intend to support over-
head.  The ceiling must be reinforced before you install the
Kit if the ceiling cannot support a redundant weight factor

five times

 the total weight of the equipment.

1. Insert the center bolt bracket from the under-side of the ceiling

tray (see Figure 1).

2. Secure the ceiling mount bracket to the center bolt bracket

using four wing nuts and washers provided.

3. Remove the tiles from the area where mounting the ceiling

tray.

4. Place the ceiling tray in its mounting location and mark the

mounting hole where the pipe will protrude from the ceiling.

5. Install the ceiling tile and ceiling tray and clamp the ceiling

tray to the ceiling track.

6. If necessary, remove outlet box knockout(s) from ceiling tray

and install electrical outlet box(es) in the opening(s).

7. Place the ceiling tray into the 24 x 24 in. (600 x 600 mm) or

24 x 48 in. (600 x 1200 mm) opening in the ceiling in place of
a ceiling tile, or mount the tray above the ceiling (see
Figure 2 for SAE applications or see Figure 3 for metric appli-
cations).

8. Using four 10 x 24 x 5/8” Phillips-head self-tapping screws in

the inside four holes for SAE applications (see Figure 2) or in
the outside four holes for metric applications (see Figure 3) of
the ceiling tray, clamp the ceiling tray to the ceiling runners.

9. Hook turnbuckles into the hanger brackets.

Secure to grid

Hook turnbuckles

Figure 2.  Bracket Attachment for USA/SAE

Figure 1.  Center Bolt Ring Attachment

Figure 3.  Bracket Attachment for Europe/Metric

Hook turnbuckles

Secure to grid

Содержание CMA440

Страница 1: ...AUTION To prevent damage to the Kit which could affect or void the Factory warranty and to the equipment that will be attached to it thoroughly study all instructions and illustrations before you begi...

Страница 2: ......

Страница 3: ...responsible for verifying that the ceiling to which the CMA 440 s reinforcing plate is anchored will safely support the combined load of all attached components or other equipment WARNING The weight o...

Страница 4: ...3 Installation Instructions CMA 440 Light Weight Suspended Ceiling Kit DIMENSIONAL DRAWING...

Страница 5: ...ark the mounting hole where the pipe will protrude from the ceiling 5 Install the ceiling tile and ceiling tray and clamp the ceiling tray to the ceiling track 6 If necessary remove outlet box knockou...

Страница 6: ...ght and twist it around itself at least four times No additional anchor is required see Figure 6 Anchoring Procedure 1 Cut the 20 ft 6 1 m tie wire into four pieces of equal length WARNING Make sure t...

Страница 7: ...anchor Pass each end through the holes in the ceiling plate reinforce ments and join them with the cable clamp Do not tighten yet 2 Attach all components and equipment to the reinforcing plate refer...

Страница 8: ...5 8 4 30 RING escutcheon 1 40 TURNBUCKLE 1 4 20 with hook and loop 4 50 SCREW lag eye 4 60 ANCHOR concrete 4 70 CLAMP wire rope for 1 8 wire 2 80 WIRE 14 gage 20 ft 6 1 m 1 90 CABLE 1 8 10 ft 3 m 1 1...

Отзывы: