E A V E T O W E R
Chief Industries, Inc. 800-359-7600
P/N - 621144
Page 26
Place the horizontal bracing into position. These connections will require (4)
3/4” x 2-1/2”
(1.90cm x 6.35cm) Grade 5 bolts with lock washer and nut.
Note that this horizontal brace will be installed on the outside of the top ear plate.
When using
20’ (6.09m) posts, mount only one (1) horizontal brace to the center ear
plate and one (1) horizontal brace to the top ear plate.
Important Note
: If you have any construction problems, additional wind loading or weight loads
that will be added to the tower, contact Chief Industries Inc. for additional information and
bracing requirements.