Note that diagonal bracing is to be installed back to back with a spacer plate in between the two
angles.
These diagonal bracing connections will require (5)
3/4” x 2-1/2” (1.90cm x 6.35cm) Grade 5
bolts with lock washer and nut. On section heights 5’ (1.52m) and smaller these connections
will require (3)
3/4” x 2-1/2” (1.90cm x 6.35cm) Grade 5 bolts with lock washer and nut. Section
heights 5’ (1.52m) and smaller do not require a bolt inside the post ear plate adjustable slot.