for technical questions, please call 1-800-444-3353.

recommended minimum Wire gauge for extension cords*

(120 or 240 volt)

namePlate

amPeres

(at full load)

extension cord lengtH

25 feet

50 feet

75 feet

100 feet 150 feet

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

table a

* based on limiting the line voltage drop to five volts at 150% of the rated amperes.

symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

Содержание 96325

Страница 1: ...Visit our website at http www harborfreight com To prevent serious injury read and understand all warnings and instructions before use Copyright 2007 by Harbor Freight Tools All rights reserved No por...

Страница 2: ...r invoice with this manual Write the invoice number on the inside of the front cover Write the product s serial number in the back of the manual near the assembly dia gram or write month and year of p...

Страница 3: ...Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators...

Страница 4: ...gerous and must be replaced Disconnect the Power Cord Plug from the power source before making any adjustments changing accessories or storing the Vacuum Such preventive safety measures reduce the ris...

Страница 5: ...aintain a safe working environment Make sure there is adequate surrounding workspace Avoid unintentional starting Make sure you are prepared to begin work before turning on the Vacuum Always keep the...

Страница 6: ...esis tance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is connected through the green wire inside the c...

Страница 7: ...city of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Table A When using more than one extension cord to make up the total length make sure each cord contain...

Страница 8: ...150 Feet 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage d...

Страница 9: ...xle as de scribed above Press the Wheel Covers 33 onto the outside of each Wheel Align the Large Wheel Base with the bottom edge of the Canister on the opposite side from the Drain and push down to lo...

Страница 10: ...ng large areas such as floors low pile carpets and rugs The head of the tool rotates a full 360 for ease of use Crevice Nozzle The Crevice Nozzle enables the operator to vacuum in close quarters corne...

Страница 11: ...eration If abnormal noise or vibration occurs during use turn the Vacuum off promptly and have the problem corrected before further use Using the Vacuum for liquids DANGER Flammability Hazard This pro...

Страница 12: ...fety Always wear ANSI approved goggles and dust mask Clear the area of children and bystanders to make sure they are not harmed by flying dirt or debris Connecting the Hose to the Exhaust allows the V...

Страница 13: ...er and dust bag 1 Dust comes from the motor cover Dust bag missing or damaged Install or replace dust bag HEPA Filter full Clean filter and allow to dry completely before continuing use 1 2 PLEASE REA...

Страница 14: ...rranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities normal wear and tear or to lack of maintenance We shall...

Страница 15: ...Page 15 SKU 96325 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM...

Отзывы: