for technical questions, please call 1-800-444-3353.

grounding

Warning!

improperly connecting the grounding wire can result in the risk of electric shock.  
check with a qualified electrician if you are in doubt as to whether the outlet is 
properly grounded.  do not modify the power cord plug provided with the tool.  
never remove the grounding prong from the plug.  do not use the tool if the 
power cord or plug is damaged.  if damaged, have it repaired by a service facil-
ity before use.  if the plug will not fit the outlet, have a proper outlet installed by 
a qualified electrician.

grounded tools:  tools WitH tHree Prong Plugs 

Tools marked with “Grounding Required” have a three wire cord and three prong 
grounding plug.  The plug must be connected to a properly grounded outlet.  If the 
tool should electrically malfunction or break down, grounding provides a low resis-
tance path to carry electricity away from the user, reducing the risk of electric shock.  
(see 3-Prong Plug and outlet.)

The grounding prong in the plug is connected through the green wire inside the 
cord to the grounding system in the tool.  The green wire in the cord must be the 
only wire connected to the tool’s grounding system and must never be attached to 
an electrically “live” terminal.  

(see 3-Prong Plug and outlet.)

Your tool must be plugged into an appropriate outlet, properly installed and grounded 
in accordance with all codes and ordinances.  The plug and outlet should look like 
those in the following illustration.  

(see 3-Prong Plug and outlet.)

3-Prong Plug and outlet

 

outlets for 2-Prong Plug

double insulated tools:  tools WitH tWo Prong Plugs

Tools marked “Double Insulated” do not require grounding.  They have a special 
double insulation system which satisfies OSHA requirements and complies with 
the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard 
Association, and the National Electrical Code.  

(see outlets for 2-Prong Plug.)

1.

2.

3.

1.

Содержание 96325

Страница 1: ...Visit our website at http www harborfreight com To prevent serious injury read and understand all warnings and instructions before use Copyright 2007 by Harbor Freight Tools All rights reserved No por...

Страница 2: ...r invoice with this manual Write the invoice number on the inside of the front cover Write the product s serial number in the back of the manual near the assembly dia gram or write month and year of p...

Страница 3: ...Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators...

Страница 4: ...gerous and must be replaced Disconnect the Power Cord Plug from the power source before making any adjustments changing accessories or storing the Vacuum Such preventive safety measures reduce the ris...

Страница 5: ...aintain a safe working environment Make sure there is adequate surrounding workspace Avoid unintentional starting Make sure you are prepared to begin work before turning on the Vacuum Always keep the...

Страница 6: ...esis tance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is connected through the green wire inside the c...

Страница 7: ...city of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Table A When using more than one extension cord to make up the total length make sure each cord contain...

Страница 8: ...150 Feet 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage d...

Страница 9: ...xle as de scribed above Press the Wheel Covers 33 onto the outside of each Wheel Align the Large Wheel Base with the bottom edge of the Canister on the opposite side from the Drain and push down to lo...

Страница 10: ...ng large areas such as floors low pile carpets and rugs The head of the tool rotates a full 360 for ease of use Crevice Nozzle The Crevice Nozzle enables the operator to vacuum in close quarters corne...

Страница 11: ...eration If abnormal noise or vibration occurs during use turn the Vacuum off promptly and have the problem corrected before further use Using the Vacuum for liquids DANGER Flammability Hazard This pro...

Страница 12: ...fety Always wear ANSI approved goggles and dust mask Clear the area of children and bystanders to make sure they are not harmed by flying dirt or debris Connecting the Hose to the Exhaust allows the V...

Страница 13: ...er and dust bag 1 Dust comes from the motor cover Dust bag missing or damaged Install or replace dust bag HEPA Filter full Clean filter and allow to dry completely before continuing use 1 2 PLEASE REA...

Страница 14: ...rranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities normal wear and tear or to lack of maintenance We shall...

Страница 15: ...Page 15 SKU 96325 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM...

Отзывы: