Chicago Electric 96325 Скачать руководство пользователя страница 11

Page 11

SKU 96325

for technical questions, please call 1-800-444-3353.

HePa filter (25) on HePa 

frame (16) with HePa cover 

(26)

HePa frame (16)

HePa filter (25) on HePa 

frame (16) 

The HEPA Filter should be rinsed with clean water periodically and allowed to 
air-dry completely before being used again. Do not use compressed air to speed 
up the drying process.
The HEPA Filter should be removed before vacuuming up liquids to prevent it from 
becoming fouled and obstructing air-flow.  

vacuuming

Before each use, inspect the general condition of the Vacuum.  Check for loose 

screws,  misalignment  or  binding  of  moving  parts,  cracked  or  broken  parts,  damaged 
electrical wiring, and any other condition that may affect its safe operation.  If abnormal 
noise or vibration occurs during use, turn the Vacuum off promptly and have the problem 
corrected before further use.

using the vacuum for liquids:

danger!  flammability Hazard: This product should never be used to vacuum up haz-

ardous liquids, such as fuel, oil, or acid.  

Unlatch and remove the Vacuum Assembly.  Make sure the Float (15) is in place 
and moves freely.

Remove the HEPA Filter and the Dust Bag, replace the HEPA Cover, reattach the 
Vacuum Assembly, and connect the Hose Connection to the lower inlet.  

  WARNING.  Make sure the Off Button (2) is depressed before plugging the 

Vacuum into a standard 120V outlet.

Attach the Utility Brush to the end of the Hose and use the attachment to vacuum 
up the water.  

When the Vacuum has reached it’s maximum capacity, the Float (15) will automati-
cally shut the unit off and the Indicator Light (4) will illuminate to indicate that the 
unit is full.  

1.

2.

3.

4.

5.

Содержание 96325

Страница 1: ...Visit our website at http www harborfreight com To prevent serious injury read and understand all warnings and instructions before use Copyright 2007 by Harbor Freight Tools All rights reserved No por...

Страница 2: ...r invoice with this manual Write the invoice number on the inside of the front cover Write the product s serial number in the back of the manual near the assembly dia gram or write month and year of p...

Страница 3: ...Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators...

Страница 4: ...gerous and must be replaced Disconnect the Power Cord Plug from the power source before making any adjustments changing accessories or storing the Vacuum Such preventive safety measures reduce the ris...

Страница 5: ...aintain a safe working environment Make sure there is adequate surrounding workspace Avoid unintentional starting Make sure you are prepared to begin work before turning on the Vacuum Always keep the...

Страница 6: ...esis tance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is connected through the green wire inside the c...

Страница 7: ...city of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Table A When using more than one extension cord to make up the total length make sure each cord contain...

Страница 8: ...150 Feet 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage d...

Страница 9: ...xle as de scribed above Press the Wheel Covers 33 onto the outside of each Wheel Align the Large Wheel Base with the bottom edge of the Canister on the opposite side from the Drain and push down to lo...

Страница 10: ...ng large areas such as floors low pile carpets and rugs The head of the tool rotates a full 360 for ease of use Crevice Nozzle The Crevice Nozzle enables the operator to vacuum in close quarters corne...

Страница 11: ...eration If abnormal noise or vibration occurs during use turn the Vacuum off promptly and have the problem corrected before further use Using the Vacuum for liquids DANGER Flammability Hazard This pro...

Страница 12: ...fety Always wear ANSI approved goggles and dust mask Clear the area of children and bystanders to make sure they are not harmed by flying dirt or debris Connecting the Hose to the Exhaust allows the V...

Страница 13: ...er and dust bag 1 Dust comes from the motor cover Dust bag missing or damaged Install or replace dust bag HEPA Filter full Clean filter and allow to dry completely before continuing use 1 2 PLEASE REA...

Страница 14: ...rranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities normal wear and tear or to lack of maintenance We shall...

Страница 15: ...Page 15 SKU 96325 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM...

Отзывы: