First turn on the Power of the QR-4000U Receiver Base Unit. Then turn on the
individual power of the SDR-916M receiver module. Select the desired channel by
pressing the channel tact switch and the corresponding channel on the Transmitter.
When Transmitter is turn on, either A or B will turn on meaning signal is being
received. Turn the volume control in clockwise direction will increase the audio
output.
What is the
RF
Test function key and how to use it ?
It is the manual scan function key. To test this function key, the transmitter must be
shut off. For model with the
RF
test key, pressing down the key is to disable the
Pilotone lock function. When A or B signal lights up when this test key is press ( the
corresponding transmitter must be swiched off.), it means that this particular
channel is in used. Select another channel and do the test again until a clean
channel is selected.
What is the SQ ( Squelch ) for ?
When a channel is in used and unpleasant interference signal is heard, turn the SQ
in clockwise direction will make the receiver less sensitive and thus less susceptible
to interference. If this still does not solve the problem, please switch over to the next
channel.
Operating instruction of QR-4000 with the 16 channels
receiver module
15
CH : 01-01
800.000
SDR-916M(for USA market)
SDR-916M(for market outside USA)
SDR-916M
UHF PLL TRUE DIVERSITY RECEIVER
PWR/Min Max
Press UP or DOWN button to view the next page
Remark : Selection between
rechargeable NiMH
and Alkaline batteries.
Operating Instructions
Making changes to the various displays
Name Display
Press
or
button to go to
the display
This display panel is for Brand and Model number. It is not possible for user to
change the setting.
Press
or
button to go to
the display
Press
SET
for about 2 seconds to enter the
SET
mode and the cursor will start
flashing. Press
SET
separately will move the cursor to the desired position where
change is needed. Press the
or
button to select the character or number and
press
SET
to make the change and move the cursor one step forward. After finishing
all the changes, press
SET
for about 3 seconds will save the changes.
Channel / Frequency Display
Press
or
button to go to
the display.
Press
SET
for about 2 seconds to enter the
SET
mode and the cursor will start
flashing.. Press
SET
each time to move the cursor one step to the desired position
to change the frequency. The first two digits on the left are GROUP ( GP ) and the
two digits on the right are CHANNEL ( CH ). There are altogether 25 preset Groups
and 40 preset Channels available for selection. Press the
or
button to select the
number. As the GP or CH number is changed, the preset frequency will appear in the
second line accordingly. After making the changes, press
SET
button for about 3
seconds will save the changes.
SENSITIVITY DISPLAY
Press
or
button to go to
the display.
Press
SET
for about 3 seconds to enter the
SET
mode and the ( N ) will flash to
accept changes. Press the
or
button to select the Normal (N) or High (H) level.
Press
SET
for about 3 seconds to save the change.
For close-mouth singing or speech application, please select N sensitivity. For
tripod-mounted speech application, please select H sensitivity.
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
NiMH : X
AKLn :
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
CHIAYO
UH-1000
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
USER
NAME
SENS SET
LEVEL (N)