Cheyenne Sol Nova Скачать руководство пользователя страница 16

31

EN

Equipment transport and 
storage conditions

ATTENTION

Damage to product caused by dropping it

If  the  SOL  Nova  is  dropped  or  falls, 
this can damage its motor and the cap 
beside the cable connection can come 
loose, exposing the cable.

 

!

Always  place  the  SOL  Nova  on  the 
SOL Nova TRAY so that it cannot roll 
away and/or fall.

 

!

If  the  SOL  Nova  does  fall  or  get 
dropped, conduct a visual inspection 
of  the  components  and  a  test  for 
unusual noises.

 

!

Hand over the SOL Nova to a specialist 
retailer for inspection if it has visible 
signs  of  damage,  if  the  operating 
noise  level  changes  strongly  or  if  it 
stops functioning normally. 

 

!

Always transport the SOL Nova and its 
accessories in their original packaging.

 

!

Always  store  the  SOL  Nova  and  its 
accessories  under  the  following 
conditions:

Ambient temperature –40 to +50°C
Relative humidity

30 to 75%

Air pressure

200 to 1060

 

hPa

Disposal of equipment 

 

!

Dispose  of  the  SOL  Nova  and 
accessories bearing the following 
designation  in  accordance  with 
the  applicable  regulations  for  used 
electronic  equipment.  If  necessary, 
consult  the  specialist  retailer  or  the 
responsible  authorities  to  learn  about 
applicable regulations.

 

!

Provide  containers  at  the  workplace 
for  legislation-compliant  disposal  of 
contaminated components.

 

!

Dispose  of  used  or  defective  safety 
cartridges in a sharps container (safety 
box) in accordance with the regulations 
applicable in your country.

10  For questions or problems

If there is radio interference:

 

!

First of all, disconnect all components, 
e.g.  the  handle  and  connecting  cable, 
from the SOL Nova.

 

!

Check all connections and reassemble 
the components.

 

!

Check  the  functions  of  the  SOL  Nova 
once again.

The SOL Nova has a temperature switch-
o

ff

.  For  safety  reasons,  the  motor  shuts 

itself  o

ff

  automatically  if  high  tempera-

tures  are  reached.  If  the  temperature 
switch-o

ff

 was triggered: 

 

!

Let  the  SOL  Nova  cool  down  to  room 
temperature and then restart it.

If  functional  problems  persist,  and  if  you 
have any questions or complaints, please 
contact the specialist retailer responsible.
To  obtain  information  about  our  current 
o

ff

ers,  the  selection  of  safety  cartridges 

and accessories, please visit our website 
www.cheyenne-tattoo.com.

Cheyenne SOL Nova

Содержание Sol Nova

Страница 1: ...sung Operating instructions Gebruiksaanwijzing Instructions Istruzioni per l uso Instrucciones de uso Manual de instruções Oδηγίες Opskrift Bruksanvisning Ohjeet Instrukcja obsługi Instrukce Navodila nt pl za uporabo Utasítás инструкции 说明 ...

Страница 2: ...1 Cheyenne SOL Nova 1 1 2 3 4 5 ...

Страница 3: ...gem Pega Motor Cabo de conexão Adaptador de cabo EL Safety cartridge Λαβή Μοτέρ Καλώδιο σύνδεσης Αντάπτορας καλωδίου DA Safety cartridge Gribestykke Drev Tilslutningskabel Kabeladapter SV Säkerhetspatron Grepp Motor Strömkabel Kabeladaptrar FI Safety cartridge turvapatruuna Kahvaosa Moottori Liitäntäjohto Johtosovitin PL Kartridż bezpieczeństwa Uchwyt Napęd Kabel zasilający Adaptery do kabla CS Be...

Страница 4: ...cting the power unit 26 5 4 Fitting the protective hose 27 5 5 Checking equipment 28 6 Using the SOL Nova 28 6 1 Setting the needle protrusion 28 6 2 Setting the piercing frequency 29 6 3 Loading with ink 29 7 Cleaning and maintaining the SOL Nova 29 7 1 Material compatibilities 29 7 2 Disinfecting surfaces 30 7 3 Cleaning surfaces 30 7 4 Cleaning handle in an ultrasonic bath 30 7 5 Sterilising ha...

Страница 5: ... notices Warning notices draw attention to the risk of personal injury and damage to materials and are structured as follows SIGNAL WORD Type of hazard Consequences Remedy Element Meaning Indicates a risk of injury Signal word Specifies the severity of the hazard see following table Type of hazard Gives the type and source of the hazard Conse quences Describes potential conse quences of non compli...

Страница 6: ... switch it off and place it safely so that it cannot roll away and fall to the ground Note the technical data quoted in these operating instructions and comply with operating transport and storage conditions see Page 24 Hand over the SOL Nova to a specialist retailer for inspection if it exhibits any external signs of damage or if it does not function in the usual manner 2 3 Important hygiene and ...

Страница 7: ...attooed Scars in the area that shall be tattooed Systemic infections and infectious dis eases e g Hepatitis type A B C D E or F HIV infection or acute local skin infections e g herpes rosacea During chemotherapy radiotherapy or high dosage corticosteroid therapy recommendation from four weeks be fore the start until four weeks after the end of the therapy Up to twelve months after a plastic sur ge...

Страница 8: ...nowledge of the risks and side effects see chapters Contra indications on page 22 and Side effects on page 22 2 7 Intended use The SOL Nova is a professional tattooing machine for the application of tattoos to the human skin in dry clean and smoke free environments and under hygienic conditions It must be prepared used and maintained in the manner described in these operating instructions In parti...

Страница 9: ... 5 to 12 6 V DC Power intake 3 W Start up current Max 2 5 A for max 200 ms Piercing frequency 25 to 150 Hz Stroke 3 5 mm Needle protrusion 0 to 4 0 mm Electrical connection 3 5 mm jack Drive Brushless DC motor Operating mode Continuous operation Diameter 33 mm Length 102 mm Weight Approx 150 g Sound emission pressure level Max 70 dB A Total vibration Max 2 5 m s 4 2 Operating conditions Ambient te...

Страница 10: ...ecommended disinfectants in chapter Material compatibilities on page 29 Switch off the power supply to the SOL Nova Check if the SOL Nova has been contaminated badly by the return flow of ink or bodily fluids In such cases perform the steps described in chapter Cleaning and maintaining the SOL Nova see Page 29 Wipe down the connecting cables the drive and the handle with a soft cloth dipped in dis...

Страница 11: ...the safety cartridge clockwise through approx 45 As you rotate it several locating points will engage audibly until the safety car tridge is firmly locked into position Check that the safety cartridge is firmly seated To remove the safety cartridge turn it anti clockwise and remove it from the handle 5 3 Connecting the power unit CAUTION Risk of short circuits If cable or cable connection is visib...

Страница 12: ... of the connecting cable supplied to the connection on the drive unit of the SOL Nova Plug the jack of the connecting cable fully into the output socket on the power unit If you are using an third party power unit connect up its terminals correctly as described in the operating instructions of the third party power unit Connect the power unit to the mains power supply Cover the Power Unit or the t...

Страница 13: ...pecialist retailer 6 Using the SOL Nova 6 1 Setting the needle protrusion CAUTION Risk of injury from excessive protrusion of needle A large needle protrusion permits a deep piercing depth If needle protrusion and piercing depth are excessive this can damage the subcutaneous layer Start with just a short length of needle protruding Switch on the power Adjust the needle protrusion while the SOL Nov...

Страница 14: ... of the safetycartridgeinthedesiredcolourofink for 2 to 3 seconds with the unit running Avoid contact with the ink container The ink is picked up by the needles Alternatively the ink can be filled into the opening on the safety cartridge using a sterile pipette 7 Cleaning and maintaining the SOL Nova CAUTION Risk of short circuits If components of the SOL Nova are dis mantled and cleaned while sti...

Страница 15: ... soft cloth dipped in a cleaning agent or a disinfectant Clean inaccessible surfaces e g the thread of the drive unit with a soft bristled nylon brush 7 4 Cleaning handle in an ultrasonic bath If the handle is severely soiled Use the cleaning agent Tickomed 1 or Tickopur R33 from manufacturer Dr H Stamm GmbH in accordance with the manufacturer s instructions Make sure that a pH value of 7 is not e...

Страница 16: ...able regulations for used electronic equipment If necessary consult the specialist retailer or the responsible authorities to learn about applicable regulations Provide containers at the workplace for legislation compliant disposal of contaminated components Dispose of used or defective safety cartridges in a sharps container safety box in accordance with the regulations applicable in your country...

Страница 17: ...al and workmanship for the product For the safety cartridges we guarantee sterility until the expiry date on the packaging providing that the packaging is sealed and undamaged and that the transport and storage conditions have been complied with For complaints relating to safety cartridges please advise us of the batch number printed on the label We do not provide warranty cover in respect of the ...

Страница 18: ...ine directive Basic Machine directive requirements used or complied with 1 1 2 1 1 3 1 1 5 1 1 6 1 2 2 1 3 1 1 3 2 1 3 3 1 3 4 1 3 7 1 5 1 1 5 2 1 5 4 1 5 5 1 5 6 1 5 8 1 5 9 1 5 11 1 5 13 1 6 1 1 6 3 1 7 1 1 1 7 4 1 7 4 1 1 7 4 2 1 7 4 3 2 1 2 1 1 2 1 2 2 2 1 2 2 1 1 The special technical documentation according to Appendix VII Part B has been established The person authorized to compile the tech...

Страница 19: ...0 3 3 ed 2 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection CISPR 14 2 1997 AMD1 2001 AMD2 2008 CISPR 14 1 2005 AMD1 2008...

Отзывы: